UMAX030211 Version 1.0.2. Preliminary Documentation – May be subject to change
76 - 85
4.4.70.
5020h Power Supply FV
Index
Subindex Data
Type
Access
PDO
Mapping
Value
Range
Default
Value
Description
5020
0
FLOAT32 RO
Yes
FLOAT32 0
Measured power supply voltage
4.4.71.
5030h CPU Temperature FV
Index
Subindex Data
Type
Access
PDO
Mapping
Value
Range
Default
Value
Description
5030
0
FLOAT32 RO
Yes
FLOAT32 0
Measured CPU internal temperature
4.4.72.
5040h FD Field Value
Index
Subindex Data
Type
Access
PDO
Mapping
Value
Range
Default
Value
Description
5040
0
UINT8
RO
No
3
3
Number of subindexes
1
FLOAT32
FLOAT32 0
FD Field Value 1
2
FD Field Value 2
3
FD Field Value 3
4.4.73.
5041h FD Set Threshold
Index
Subindex Data
Type
Access
PDO
Mapping
Value
Range
Default
Value
Description
5041
0
UINT8
RO
No
3
3
Number of subindexes
1
UINT16
RW
UINT16
1100
FD Set Threshold 1 (Temperature SET)
2
500
FD Set Threshold 2 (VPS SET High)
3
90
FD Set Threshold 3 (VPS SET Low)
4.4.74.
5042h FD Clear Threshold
Index
Subindex Data
Type
Access
PDO
Mapping
Value
Range
Default
Value
Description
5042
0
UINT8
RO
No
3
3
Number of subindexes
1
UINT16
RW
UINT16
850
FD Set Threshold 1 (Temperature CLR)
2
480
FD Set Threshold 2 (VPS CLR High)
3
120
FD Set Threshold 3 (VPS CLR Low)
4.4.75.
5050h FD Enable 3 Faults
Index
Subindex Data
Type
Access
PDO
Mapping
Value
Range
Default
Value
Description
5050
0
UINT8
RW
No
0-7
7
Enable diagnostics:
bit 0 – VPS
bit 1 – CPU temeperature