UMAX030211 Version 1.0.2. Preliminary Documentation – May be subject to change
46 - 85
The module will send the following response (any other response is a failure).
Item Value
COB-ID
0x7E4
Length
3
Data 0
0x11
(cs=17 for configure node-id)
Data 1
0x00
Data 2
0x00
Save the configuration by
sending
the following message:
Item Value
COB-ID
0x7E5
Length
1
Data 0
0x17
(cs=23 for store configuration)
The module will send the following response (any other response is a failure)
Item Value
COB-ID
0x7E4
Length
3
Data 0
0x17
(cs=23 for store configuration)
Data 1
0x00
Data 2
0x00
Set the module state to LSS-operation by
sending
the following message: (Note, the
module will reset itself back to the pre-operational state)
Item Value
COB-ID
0x7E5
Length
2
Data 0
0x04
(cs=4 for switch state global)
Data 1
0x00
(switches to waiting state)
4.1.1.2.
Setting Baud rate
Set the module state to LSS-configuration by sending the following message:
Item Value
COB-ID
0x7E5
Length
2
Data 0
0x04
(cs=4 for switch state global)
Data 1
0x01
(switches to configuration state)
Set the baud rate by sending the following message:
Item Value
COB-ID
0x7E5
Length
3
Data 0
0x13
(cs=19 for configure bit timing parameters)
Data 1
0x00
(switches to waiting state)
Data 2
Index
(select baudrate index per Table 32)