UMAX030211 Version 1.0.2. Preliminary Documentation – May be subject to change
47 - 85
Index Bit
Rate
0
1 Mbit/s
1
800 kbit/s
2
500 kbit/s
3
250 kbit/s
4
125 kbit/s (default)
5
reserved
(100 kbit/s)
6
50 kbit/s
7
20 kbit/s
8
10 kbit/s
Table 27 – LSS Baud rate Indices
The module will send the following response (any other response is a failure):
Item Value
COB-ID
0x7E4
Length
3
Data 0
0x13
(cs=19 for configure bit timing parameters)
Data 1
0x00
Data 2
0x00
Activate bit timing parameters by sending the following message:
Item Value
COB-ID
0x7E5
Length
3
Data 0
0x15
(cs=19 for activate bit timing parameters)
Data 1
<delay_lsb>
Data 2
<delay_msb>
The delay individually defines the duration of the two periods of time to wait until the bit timing
parameters switch is done (first period) and before transmitting any CAN message with the new bit
timing parameters after performing the switch (second period). The time unit of switch delay is 1 ms.
Save the configuration by sending the following message (on the NEW baud rate):
Item Value
COB-ID
0x7E5
Length
1
Data 0
0x17
(cs=23 for store configuration)
The module will send the following response (any other response is a failure):
Item Value
COB-ID
0x7E4
Length
3
Data 0
0x17
(cs=23 for store configuration)
Data 1
0x00
Data 2
0x00