Version 2.0.3 Preliminary Documentation – May be Subject to Change 22-36
4.4.
Output Control Setpoints
There are four setpoints per channel that are associated with the output and how it is controlled. This
section describes how changing these values will effect how the output responds.
Name Range
Default Notes
Output Type
0: 0 to 5 Volt
1: -5 to 5 Volt
2: 0 to 10 Volt
3: -10 to 10 Volt
4: 0 to 20 Milliamp
0: 0 to 5 Volt
See section
1.4
for more details about
each output type.
Output
Response
0: Output Disabled
1: Single Profile, Single Slope
2: Single Profile, Dual Slope
3: Dual Profile A, Single Slope
4: Dual Profile A, Dual Slope
5: Dual Profile B, Single Slope
6: Dual Profile B, Dual Slope
1: Single Profile,
Single Slope
If a single slope response is selected, the
values in the input and output Breakpoint
setpoints are ignored.
Control Input
1: AIN1
2: AIN2
3: AIN3
4: AIN4
5: AIN5
6: AIN6
7: AIN7
8: AIN8
9: J1939 Command
9: J1939
Command
Whether an input will act as an analog
input or a digital input will depend on the
Input Sensor Type selected for that input.
(see section
4.1
)
When 9: J1939 Command is selected, the
input setpoints shown in Figure
1
will be
the Command parameters described in
section
4.6
.
Enable Input
0: Enable Not Used
1: AIN1
2: AIN2
3: AIN3
4: AIN4
5: AIN5
6: AIN6
7: AIN7
8: AIN8
0: Enable Not
Used
If an input is selected as an enable input,
but it is NOT setup as a digital input, then
the Enable Input will be ON when the
input is greater than or equal to Maximum
Input, and OFF when the input is less
than or equal to Minimum Input. Input
values between these two limits will have
no effect on the state of the Enable Input.
4.5.
Output Profile Setpoints
There are five setpoints that will determine the output's behaviour, depending on the profile selected in
"Output Response." See Figures
1
,
2
and
3
in section 1.4 for more details about the output vs input profiles.
Name Range
Default
Notes
Minimum
Full Range of Output
Type=0 to 5V
Type=-5V to 5V
Type=0 to 10V
Type=-10 to 10V
Type=0 to 20mA
0V
-5V
0V
-10V
4mA
Breakpoint
Full Range of Output
Type=0 to 5V
Type=-5V to 5V
Type=0 to 10V
Type=-10 to 10V
Type=0 to 20mA
2.5V
0V
5V
0V
12mA
This setpoint is ignored when a "Single
Slope" response has been selected.
Maximum
Full Range of Output
Type=0 to 5V
Type=-5V to 5V
Type=0 to 10V
Type=-10 to 10V
Type=0 to 20mA
5V
5V
10V
10V
20mA