Initialization
The initialization is subdivided in 3 configuration phases.
Phase 1: Tuners.
∂
LNB settings, DiSEqC settings,
∂
Transponder frequency and transponder search run.
Phase 2: Chosse of programmes, programme arrangement.
∂
Multiplexing after programme filtering (Remux mode)
∂
Transponder crossing multiplexing of FTA programmes (Cross-Multiplex mode)
∂
LCN (Logical Channel Numbering)
Phase 3: Modulators.
∂
Channel spacing, output channel, fine calibration and output level.
∂
Modulation, code rate, guard interval, transmission mode.
3.3.
Initialization phase 1
During the first phase of the initialization, the tuner settings required for the scan are made and the station
scanning is carried out. The four tuners work independently from each other and after the same principle.
3.3.1.
DVB-S (für 8PSK/QPSK- und für Multituner-Kassetten)
Choose the tuner with the button
Tuner 1…4
.
Configure the needed settings for all tuners.
The SAT IF frequency of the transponder is
entered in the input field "
Frequency
(MHz)".
The input fields "
LOF Low Band
(MHz)"
and "
LOF High Band
(MHz)" correspond to
the oscillator frequencies of the LNB in low
and high band.
The default settings of the oscillator
frequencies are 9,750 MHz for the low band
and 10,600 MHz for the high band.
In the optional field "
Polarisation
", you can
switch from horizontal to vertical.
In the optional field "
DiSEqC
", the DiSEqC
command signals can be turned off or set to
switch a DiSEqC-enabled multi switch on the
positions 1 to 4.
If required, the operating voltage for the LNB
can be switched off via the optional field
"
LNB power supply
".
After all settings have been made, click the button
SCAN
.
A rotating circle is shown on the right side during the scanning process.