Field of application
The devices are suited only for distributing HDMI signals in the house! If the
device is used for other purposes, no warranty is given!
Product discription
9
HKM 40-00 = 4 x HDMI in 1 × DVB-C/T
9
Converts the HDMI resolution 1080p@50/60 Hz
to DVB-compliant 1080p@25/30 Hz
9
Web-based configuration | Remote maintenance
9
Suitable for AXING SMARTPortal
9
Can be used for wall mounting or as a 19“ unit
9
Built-in power supply
Scope of delivery:
1 × HKM 40-00 Encoder/Modulator
1 × AC power cord
1 × Quick start guide
Mounting and Installation:
Before mounting and installation, pull the mains plug!
The encoder/modulator must be connected to the equipotential bonding
according to EN 60728-11. Use the equipotential bonding connection of
the device (2).
The encoder/modulator can be mounted on either at the wall or be mounted in
a 19 „rack.
Wall mounting
The encoder/modulator are factory-fitted with wall brackets.
Note: The unit must be wall mounted with at least 5 cm clearance along the 4
sides.
The installation must be carried out on an even and vertical surface (any
unevenness must be compensated).
Fix the device with with minimum four pcs of 4 × 30 mm screws.
Mounting in a 19“ rack
Note: For 19-inch rack mounting, there must be at least 5 cm clearance in front
of and behind the unit.
Remove the wall bracket from the housing of the encoder/modulator.
Mount the front plate HKZ 1-00 onto the HKM 40-00.
Slide the encoder/modulator into the 19 „rack.
Fix the encoder/modulator with four screws.
Connection to HDMI
The HKM 40-00 has four HDMI inputs. Connect them to four HDMI sources.
Power supply
The HKM has a built-in power supply. Connect this to an electrical outlet
(100...240 VAC / 50 ... 60 Hz).
Note:
You can call up the detailed operation instructions for download by entering
the article in the search field at www.axing.com.
Display elements and connectors
1
4 LEDs for the input signal:
green
= HDMI signal ok
green flashing = low resolution signal
out
= no HDMI signal
2
Equipotential bonding connection
3
Mains connection
4
RF output
5
Test port -30 dB
6
RF input 5…8
7
RJ45 Ethernet connector
Configuration:
The device is configured via the graphical user interface. To access the
user interface, you need a standard PC/laptop with a network interface,
a commercially available network cable and the actual version of the
installed web browser.
Accessing the configuration interface:
Default IP address:
192.168.0.168
Subnet mask:
255.255.255.0
The configuration screen is password-protected:
Enter the default password Ramsen8262 (After the first log-in, the pass-
word should be changed).