background image

Manufacturer

AXING AG 

Gewerbehaus Moskau

 8262 Ramsen

EEA contact address

Bechler GmbH

Am Rebberg 44

 78239 Rielasingen

State of the art 2018-12-19

Technical improvements, changes in design, printing- and other errors expected.

Safety advices:

 

The installation of the device must be carried out only by a professional in 

accordance with the applicable VDE directives. In case of incorrect installati-

on, no liability is assumed.

 

Never open the device. There are no parts to be maintained by the user inside 

the device, however, lethal voltages are present. This also applies to cleaning 

the device or working on the connections.

 

Use only the mains cable connected to the device or the enclosed power 

supply unit. Never replace any parts or make any modifications to the mains 

cable and the power supply unit. Otherwise, there is a risk of death.

 

If a replaceable fuse is available, pull out the mains plug before replacing 

the fuse. Replace defective fuses only by standardized fuses with the same 

nominal value.

 

If you intend not to use the device for a longer period of time, we recom-

mend you to completely disconnect the device from the mains for safety 

reasons and for saving energy by pulling out the mains plug.

 

Let the device adjust to the room temperature before commissioning, in 

particular if condensation is present on the device, or if it was exposed to 

large temperature fluctuations. 

 

The device must be operated only in moderate climate.

 

The device must be operated only in dry rooms. In damp rooms or outdoors, 

there is a risk of short-circuits (attention: risk of fire) or electrical shocks 

(attention: risk of death).

 

The device shall not be exposed to dripping or splashing. Do not place 

objects filled with liquids such as vases on the device.

 

Plan the mounting or installation location such that you can easily reach the 

mains plug and interrupt the electric circuit in dangerous situations. Select 

the mounting or installation location such that children cannot play near the 

device and its connections without supervision. The mounting or installation 

location must allow a safe installation of all connected cables. Power supply 

cables and supply cables must not be damaged or squeezed by any objects.

 

Operate the device only on a flat, firm surface and protect it against uninten-

tional movements.

 

Never expose the device to direct solar irradiation and avoid direct vicinity of 

heat sources (e.g. heaters, other electrical appliances, fireplace, etc.). It must 

be always ensured that devices with cooling elements or ventilation slots are 

not covered or obstructed. 

 

Ensure generous air circulation around the device. This will prevent possible 

damage to device and risk of fire due to overheating. It must be always 

ensured that cables are not located near heat sources (e.g. heaters, other 

electrical appliances, fireplace, etc.). 

 

The unit must be wall mounted with at least 5 cm clearance along the 4 

sides. For 19-inch rack mounting, there must be at least 5 cm clearance in 

front of and behind the unit.

 

In particular, the warranty and liability shall be excluded for the consequen-

ces of incorrect use, in case of incorrect modifications or repair work carried 

out by the customer. Use the device only as described in the operating 

instructions and in particular according to the state-of-the-art.

 

The antenna system must be installed and grounded according to the current 

DIN EN 60728-11 standard.

HKM 40-00

premium

-line

HDMI | DVB-C/T  
encoder/modulator

Quick start guide

Technical data:

Herewith AXING AG declares that the marked products comply with the valid 

guidelines. You can call up the complete EU declaration of conformity for 

download by entering the article in the search field at www.axing.com.

WEEE Nr. DE26869279 | Electrical and electronic components must not be 

disposed of as residual waste, it must be disposed of separately.

Number of inputs

4 × HDMI

Video Encoder

H.264

Intput video resolution

1080p@50 Hz | 1080p@60 Hz

Max. bit rate per channel

16 Mbit/s

Audio Encoder

MPEG1 audio layer II

Output frequency range

45......862 MHz

Output channels adjustable

E2.....E69

Output level adjustable

90…105 dBµV

Output modulation

QAM 16/32/64/128/256 | QAM 16/64

Output video resolution

1080p@25 Hz | 1080p@30 Hz

Output transmission symbol rate

1-7,5 M‘Symbol sec 

Output modulation MER

≥ 40 dB @ DVB-C | ≥ 36 dB @ DVB-T

Output modulation FEC (DVB-T)

1/2, 2/3, 3/4, 5/6, 7/8

Output guard interval (DVB-T)

1/4, 1/8, 1/16, 1/32

Output connector

1 × F

Output test port

1 × F | -30 dB

Data interface

1 × RJ45

Operation voltage

100…240 VAC/50…60 Hz

Power consumption

50 W

Ambient temperature range (acc. to 
EN 60065)

-10°C…+50°C

Dimensions (W × H × D) appr.

480 × 253 × 47 mm