background image

BZU 10-00

Signal tester CATV

Operation Instructions

Safety advice:

4

Switch off all devices befor the Installation

4

Installation and repairs to the equipment may only be carried out by 
technicians observing the current VDE guidelines.  No liability will be 
assumed in the case of faulty installation and commissioning.

4

Before opening the equipment remove the power supply, otherwise 
there is danger of of short-circuit. This is also valid for cleaning the 
equipment or working on the connections. 

4

The equipment may only be operated in dry rooms. In humid rooms or 
outdoors there is danger of short-circuit (caution: risk of fire).

4

Choose the location of installation or mounting such that children may 
not play unsupervised near the equipment and its connections. The 
location of installation or mounting must allow a safe installation of all 
cables connected. Power feeding cables as well as feeder lines may not 
be damaged or clamped by objects of any kind. To prevent damage to 
your equipment and to avoid possible peripheral damages, the devices 
foreseen for wall mounting may only be installed on a flat surface.

4

Choose the location of installation or mounting so that under no 
circumstances liquids or objects can get into the equipment (e.g. 
condensation, water coming from leaking roofs or flowing water, etc.).

4

Avoid exposure of the equipment to direct sunlight and to other heat 
sources (e. g. radiators. other electrical devices, chimney, etc.). Devices 
that are equipped with heat sinks or ventilation slots must under no 
circum-stances be covered or blocked. Also ensure for a generous air 
circulation around the equipment. In this way you avoid possible 
damage to the equipment as well as a risk of fire caused by overheating. 
Absolutely avoid that cables come near any source of heat (e.g. 
radioators, other electrical devices, chimney, etc.).

Technical specifications:

Operating voltage ..................................................................9 V DC battery
Max.current ..............................................................................50 mA (max)
Power consumtion ...........................................................................450 mW
Frequency range
Analogue ......................................................188…230 MHz (CH 7...CH 12)
Digital ................................................................334...374 MHz (S 25...S 29)
Impedance........................................................................................75 Ohm
Connectors.................................................................................1 x F female
Level range ...............................................................................60...95 dBµV
Resolution.......................................................................5 dBµV ± 2,5 dBµV
Dimensions.........................................................................60x 120x 26 mm

WEEE Nr. 

DE14023300

Your device is marked with the WEEE symbol (Waste Electronics 
and Electrical Equipment). This means that the electrical and 
electronic components must not be disposed of as residual waste. 
Used electrical and electronic components must be disposed of 
separately.

State of the art 

6-08-08 Technical changes, design modifications, 

201

errors and misprints are subject to change without prior notice.

Manufacturer
AXING AG 
Gewerbehaus Moskau
     8262 Ramsen 

EWR contact adress
Bechler GmbH
Am Rebberg 44
     78239 Rielasingen

Содержание BZU 10-00

Страница 1: ... sowie Zuführungskabel dürfen nicht durch irgendwelche Gegenstände beschädigt oder gequetscht werden 4 Wählen Sie einen Montage bzw Aufstellungsort an dem unter keinen Umständen Flüssigkeiten oder Gegenstände in das Gerät gelangen können z B Kondenswasser Dachundichtigkeiten Gießwasser etc 4 Setzen Sie das Gerät niemals direkter Sonneneinstrahlung aus und vermeiden Sie die direkte Nähe von Wärrmeq...

Страница 2: ...aus dem AXING Sortiment Der BZU 10 00 ersetzt kein Messgerät und ermittelt auch keine Schräglagen Bedienung Der Signaltester wird über das Kabel MAK 30 80 und den Adapter CFA 2 00 z B am TV Ausgang einer Antennensteckdose angeschlossen Je nach Signal wird durch Drücken der Taste Analog bzw Digital der Pegel an den LEDs des BZU 10 00 angezeigt Der Pegel in dBµV kann direkt rechts neben der LED abge...

Страница 3: ... equipment e g condensation water coming from leaking roofs or flowing water etc 4 Avoid exposure of the equipment to direct sunlight and to other heat sources e g radiators other electrical devices chimney etc Devices that are equipped with heat sinks or ventilation slots must under no circum stances be covered or blocked Also ensure for a generous air circulation around the equipment In this way ...

Страница 4: ... include antenna sockets service area interfaces antenna cables HF outputs of DVD recorders or PC TV cards It can measure analogue and digital channels in the frequency range of the KDG KBW and Unity Media cable networks It cannot measure DVB T signals They can be measured by the TZU 22 01 from the AXING product range The BZU 10 00 is not a replacement for a measuring instrument and nor does it de...

Отзывы: