Axi STS 6003 Скачать руководство пользователя страница 24

 

REV03016703010220 

23 

AXI International Limited Warranty 

AXI International makes every effort to assure that its products meet high quality and durability standards and expressly 
warrants the products described herein against defects in material and workmanship for a period of one (1) year from the 
date of purchase. This warranty is not intended to supplant normal inspection, care and service of the products covered 
by the user, and shall not obligate AXI International to provide free service during the warranty period to correct breakage, 
maladjustment, or other difficulties arising out of abuse, misuse, or improper care and maintenance of such products. Our 
express warranty is subject to the following terms and conditions:  
 
This warranty shall only extend to and is only for the benefit of original purchaser(s), or end customer(s) who use the 
products covered hereby and subject to the terms and conditions herein. This warranty is not an on-site warranty. Travel 
requests will be at the discretion of AXI International. Defective systems and ancillary products will require a return 
authorization number and shipping to AXI International’s factory in Fort Myers, FL. Any warranty claim received by AXI 
International after one (1) year from the date of purchase will not be honored even if it is claimed that the defect occurred 
prior to one (1) year from the date of purchase. Claims outside of this one (1) year period, and for claims not listed within, 
payment, repair, or service will be awarded at the sole and exclusive discretion of AXI International.  
 

This Warranty shall NOT apply to the following:  

1.

 

Damage or deterioration caused by normal wear and tear.  

2.

 

Failures caused by any external cause or act of God, such as accident, collision, theft, vandalism, riots, wars, re, 
freezing, lightning, earthquakes, windstorms, hail, volcanic eruptions, floods, tornados or hurricanes.  

3.

 

Failures due to alterations, adjustments, unauthorized changes to the product(s), neglect or improper storage, 
repair and/or maintenance.  

4.

 

Failures due to abuse or application of the product(s) for uses other than for which it/they are designed or 
intended by AXI International, including but not limited to, improper installation or location in a harsh, corrosive or 
saltwater environment.  

5.

 

Failures resulting from attachments, accessory items, and parts not sold by AXI International.  

6.

 

Repairs by any party other than those authorized by AXI International.  

7.

 

Failures resulting from user’s delay in making the product available for inspection by AXI International after 
notifying AXI International of a potential product problem.  

8.

 

Cosmetic damage, discoloration, rusting, corrosion or scratches from applied paint.  

9.

 

Replacement of consumables such as, but not limited to, fuses, lamps, filters, etc.  

10.

 

Additional expenses for repair after normal business hours, i.e., overtime or holiday labor rates.  

11.

 

Expenses for rental of equipment during downtime and/or performance of warranty repairs.  

12.

 

Expenses related to investigating performance complaints and/or troubleshooting where no manufacturing defect 
is found.  

 
In addition to the limitations above, this warranty shall not apply to products (1) which have been tampered with, altered or 
repaired by anyone other than AXI International without the express prior written consent of AXI International (2) which 
have been installed improperly or subject to misuse, abuse, accident, negligence of others, improper operation or 
maintenance, neglect or modification, or (3) which have had the serial number altered, defaced or removed.  
The liability of AXI International under this warranty is limited to the repair or replacement of the defective product. AXI 
International assumes NO LIABILITY for labor charges or other costs incurred by any purchaser incidental to the service, 
adjustment, repair, return, removal or replacement of products. AXI INTERNATIONAL ASSUMES NO LIABILITY FOR 
ANY GENERAL, SPECIAL, INCIDENTAL, CONSEQUENTIAL, CONTINGENT OR OTHER DAMAGES UNDER ANY 
WARRANTY, EXPRESS OR IMPLIED, OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE OR 
OTHERWISE, WITH THE RESPECT TO THE PRODUCTS COVERED BY THIS WARRANTY POLICY, EXCEPT AS 
EXPRESSLY PROVIDED FOR HEREIN. AXI INTERNATIONAL ASSUMES NO LIABILITY FOR ANY GENERAL, 
SPECIAL, INCIDENTAL, CONSEQUENTIAL, CONTINGENT OR OTHER DAMAGES EVEN IF SUCH DAMAGES ARE A 
DIRECT RESULT OF AXI INTERNATIONAL’S NEGLIGENCE. NO EMPLOYEE, AGENT, REPRESENTATIVE OR 
DISTRIBUTOR IS AUTHORIZED TO MAKE ANY WARRANTY ON BEHALF OF AXI INTERNATIONAL OTHER THAN 
THE EXPRESS WARRANTY PROVIDED FOR HEREIN.  

Содержание STS 6003

Страница 1: ...Dr Fort Myers FL 33905 239 690 9589 Toll Free 877 425 4239 FAX 239 690 1195 www AXI International com STS STS 6003 7003 Instruction Operating Maintenance Manual ENCLOSED FUEL MAINTENANCE SYSTEM REV03...

Страница 2: ...REV03016703010220 1...

Страница 3: ...rical 11 Field Connections If Applicable 11 Plumbing 11 Typical Plumbing Installation Schematically 12 Important Installation Precautions 12 Multi Tank Installation If Applicable 12 Controller 14 Sett...

Страница 4: ...tom Troubleshooting Guide 22 AXI International Limited Warranty 23 Warranty Claim Procedure 24 Technical Assistance and Ordering 25 Accessories and Additional Configuration Parameters 25 Replacement F...

Страница 5: ...C Operating Temperature 7000 Series 41 122 F 5 50 C Electrical 120V 60Hz 15A 1Ph or 230V 50Hz 15A 1Ph Pump 1 3 HP Spur Gear Pump Suction Capability Primed 15ft vertical lift or 100ft horizontal run li...

Страница 6: ...Water Detection Alarm Module Vacuum Pressure Switches Flow Switch Leak Detection Float Switch Inlet and Outlet Isolation Ball Valves Pump Motor 1 3 HP Gear Pump Primary Filter Water Separator Fuel Fil...

Страница 7: ...in Valve Basket Strainer Water Collection Drum o High Water Level Float Switch Manual Additive Injection If Applicable System Ball Valve Additive Injection Port Injection Port Ball Valve Auto Additive...

Страница 8: ...ion o Activated when the Vacuum Switch placed on the suction side of the pump set detects a reading above the factory set point The system will go into an alarm state and the pump will not be allowed...

Страница 9: ...or operate system without high fuel level alarms from both tanks tied into the control panel Frequently test overflow alarms for proper functionality and pump shutdown Auto Water Drain AWD If Applicab...

Страница 10: ...the treatment ratio For example 5 Gallon Jug of AFC treats 25 000 gallons of fuel so enter 1 5000 6 Once this information is entered press the START button to begin the injection process 7 There is a...

Страница 11: ...lectrical problems Immediately report or note any damages to the shipper Checklist If the packing crate shows signs of damage inspect the system for damage Check the entire system for damage that coul...

Страница 12: ...to the ground studs provided as shown on the provided drawings After the initial wiring of the system check operation to ensure that the motor is running in the correct direction If the motor is runn...

Страница 13: ...ed piping size Ref Page 4 Inlet Outlet Port or more with no additional flow restrictions That includes valves 90 degree connectors or other plumbing accessories For continuous optimal performance make...

Страница 14: ...vided electrical drawings must be wired to the Normally Closed High Level Alarm Contacts on both tanks to avoid overfilling of either tank and potential spills This is a very important safety feature...

Страница 15: ...the arrow key to select the Timer and Press OK 5 Use the arrow keys to select the desired field and press OK to edit 6 Use the left and right arrow keys to select the day days of the week the system...

Страница 16: ...IP Address 1 From the Main Menu press the CONFIG button 2 Input 9999 and press the enter key 3 Push IP Config and continue onto the next page 4 Enter the desired values for the PLC IP Address PLC IP...

Страница 17: ...m gauge on the input side of the pump The gauge should read no more than 15 HG vacuum maximum under normal conditions Vacuum gauge readings reaching 16 HG indicate excessive debris in the primary filt...

Страница 18: ...ssioning section Flow Switch When the flow rate drops below the predetermined set point on the flow switch i e 10 GPM the switch will trigger a signal to shut down the pump If the set point is incorre...

Страница 19: ...igh Pressure alarm should be indicated on the System Controller Open the outlet ball valve again Reset the alarm by pushing the Alarm Reset button on the enclosure door panel Water Sensor Jump the Wat...

Страница 20: ...hs Servicing the Primary Filter Water Separator Clogged primary filter elements restrict the flow of fuel resulting in the system s vacuum gauge indicating a pressure drop The gauge reads the conditio...

Страница 21: ...rn the enclosure door panel selector switch to its original position 9 Check for leaks when re starting and pressurizing the system Note Disposal of fuel associated waste and filters must be in accord...

Страница 22: ...icing of Water Separator 1 Keep a fuel waste container under the Manual Drain Port 2 Open the bleed screw on top of the Water Separator to break vacuum 3 Open the AWD Isolation Ball Valve and Manual D...

Страница 23: ...ve water in tank 2 Restriction in plumbing on discharge side too high 3 Head on discharge side too high 4 Check valve stuck or defective 5 Outlet ball valve not fully open 6 Discharge line clogged Pum...

Страница 24: ...t limited to improper installation or location in a harsh corrosive or saltwater environment 5 Failures resulting from attachments accessory items and parts not sold by AXI International 6 Repairs by...

Страница 25: ...purchase model number serial number and a detailed explanation of the problem you are experiencing The Customer Service Representative may at the discretion of AXI International arrange for a Field E...

Страница 26: ...eters SYSTEM ALARMS Switches and timer delays Type Default Set point Default Timer delay sec AXi international s part number Vacuumswitch 16 in hg 5 0 aa 0528 Pressure switch 22 psi 0 0 aa 0526 Flowsw...

Отзывы: