3. Technical Data
3.1 Materials in Contact with the Product
See Pic. 2-1:
Housing (pos. 1)
1.4301 / 1.4307 / 1.4404 / 1.4435
Insert (pos. 4)
1.4404 / 1.4435
Sealring (pos. 3; 5)
selected acc. to operating conditions
Sealing material
EPDM: max. short-time sterilisation temperature: 140 °C
VMQ: max. short-time sterilisation temperature: 130 °C
FKM: max. short-time sterilisation temperature: 130 °C
Max. temperature short-term 15 - 20 minutes, depending on the medium.
CAUTION
The dirt trap‘s area of application shall always be adjusted to the relevant
operating conditions and the materials that come into contact with the product.
Surfaces
Outer
surface:
metal
bright/polished
Inner surfache in contact with product:
Ra < 0.8 µm (except weld seams and can)
NOTE
For technical datasheet please refer to the current AWH catalogue.
9
If used with free-from-chlorine potable water, the service life of the strainer will be approx. 10 years.
If used with aggressive media, the service life will be shorter.
3.2 Connection Variants, Type Series, Dimensions
NOTE
Typical connection confi gurations of the dirt trap are shown below. The mounting
position should be done according to the fi gures. For dimensions refer to the table
overleaf.
You can fi nd the technical datas heet on the product pages of the current
AWH „Strainers and Sight Glases“ catalogue online or you can request it directly
from Armaturenwerk Hötensleben GmbH. The names of the data sheet and the
operating instructions must be identical.