Award PPS1201 Скачать руководство пользователя страница 8

 

 

 

 

 

EN 

8

 

L

T1

T2

T3

T4

S1

L

S1

T1

T2

T3

T4

USE

 

 

 

 

 

 

 

 

 

 

Control panel 

Button

 

Led

 

Function

 

L

 

Turns the lights on/off at maximum strength. 

T1

 

Fixed 

Turns the motor on/off at speed one. 

T2

 

Fixed 

Turns the Motor on at speed two. 

 

 

Press and hold the button for approximately 3 seconds, with all the loads turned 
off  (Motor  and  Lights),  to  turn  the  Activated  Charcoal  Filter  alarm  on.  The 
relevant LED flashes twice to confirm. 

To turn the alarm off, press the button again and hold for at least 3 seconds. The 
relevant LED flashes once. 

T3

 

Fixed 

Turns the Motor on at speed three. 

 

 

Press and hold the button for approximately 3 seconds, with all the loads turned 
off (Motor and Lights), to perform a reset of Filter saturation alarm. The LED 

S1 

flashes three times. 

T4

 

Fixed 

Turns the Motor on at INTENSIVE Speed. 

This  speed  is  timed  to  run  for  10  minutes.  At  the  end  of  this  time,  the  system 
returns  automatically  to  the  speed  that  was  set  before.  If  it  is  activated  with  the 
motor turned off, the hood will switch to OFF at the end of the time. 

 

 

Press and hold for 3 seconds to enable the remote control, indicated by the LED 
flashing twice. 

Press and hold for 3 seconds to disable the remote control, indicated by the LED 
flashing just once. 

S1

 

Fixed 

Signals the Metal Grease Filter saturation alarm, indicating that it is necessary to 
wash  the filters.  The  alarm  is  triggered  after  the  Hood has  been  in  operation for 
100 working hours. (Reset see the parag. Maintenance) 

 

Flashing  When  this  is  activated,  it  signals  the  Activated  Charcoal  Filter  saturation  alarm, 

indicating that the filter  must be changed; the Metal Grease Filters  must  also be 
washed. The Activated Charcoal Filter saturation alarm comes 

 into  operation  after  the  Hood  has  been  working  for  200  hours.  (Activation  and 
Reset see the parag. Maintenance) 

 
 

Содержание PPS1201

Страница 1: ...Instructions Manual Manuel d Instructions Bedienungsanleitung Manual de instrucciones ǽȗȥıțȢȔİțȡ ȡİșȗțȬȟ ɋɮɥɩɝɩɟɬɭɝɩ ɪɩ ɸɥɬɪɦɮɛɭɛɱɣɣ ...

Страница 2: ...7 INHALTSVERZEICHNIS EMPFEHLUNGEN UND HINWEISE 19 CHARAKTERISTIKEN 20 MONTAGE 21 BEDIENUNG 24 WARTUNG 25 ÍNDICE CONSEJOS Y SUGERENCIAS 27 CARACTERÍSTICAS 28 INSTALACIÓN 29 USO 32 MANTENIMIENTO 33 ȇǽȈȀǽȌȆȃǽȄǺ ȈȊȂǺȅȊȁǼȈ Ȁǹǿ ȈȊȈȉǹȈǼǿȈ 35 ȋǹȇǹȀȉǾȇǿȈȉǿȀǹ 36 ǼīȀǹȉǹȈȉǹȈǾ 37 ȋȇǾȈǾ 40 ȈȊȃȉǾȇǾȈǾ 41 ɎɅȻɂȻɍɀɆɗ ɋɈȼȿɌɕ ɂ ɊȿɄɈɆȿɇȾȺɐɂɂ 43 ɏȺɊȺɄɌȿɊɂɋɌɂɄɂ 44 ɍɋɌȺɇɈȼɄȺ 45 ɗɄɋɉɅɍȺɌȺɐɂə 48 ɍɏɈȾ 49 EN FR DE ES GR RU ...

Страница 3: ...edepartment inordertopreventanyrisks Allairductingregulationsmustbecompliedwith USE Theextractorhoodhasbeendesignedexclusivelyfordomesticusetoeliminatekitchensmells Neverusethehoodforpurposesotherthanforwhichithasbeendesigned Neverleavehighnakedflamesunderthehoodwhenitisinoperation Adjust the flame intensity to direct it onto the bottom of the pan only making sure that it does not engulfthesides D...

Страница 4: ...th Controls Light Fan unit Filters 2 2 1 Lower chimney 8 1 Directional Grille ø 125 mm 9 1 Reduction Flange ø 150 120 mm Ref Q ty Installation Components 12a 4 Screws 3 9 x 13 12c 2 Screws 2 9 x 9 5 12e 2 Screws 2 9 x 9 5 Washer under head Q ty Documentation 1 Instruction Manual 2 2 12c 1 9 12e 8 12a ...

Страница 5: ...dge of the unit excluding any doors Remove grease filters Screw the hood canopy to the unit from the inside using the screws 12a 3 9 x 13 provided Loosen the screws fixing the spacer and adjust it to the correct position before fastening completely WARNING The Hood Canopy must be fitted into the Unit before it is fixed to the wall ...

Страница 6: ...lamps not sup plied Remove possible charcoal filters 9 ø120 ø150 RECIRCULATION VERSION AIR OUTLET Cut a hole ø 125 mm in any shelf that may be positioned over the hood Insert the reducer flange 9 on the hood body outlet Connect the flange to the outlet on the shelf over the hood by using a flexible or rigid pipe ø120 mm Fix the pipe in position using sufficient pipe clamps not sup plied Fix the ai...

Страница 7: ...he socket placed on the side of the fan Fitting the Chimney Lower chimney Open the two side pieces of the Chimney out slightly insert them over the hood canopy and bring them back together again until they are in contact Fasten the Chimney to the sides of the Hood canopy using 2 Screws 12c 2 9 x 9 5 provided without tightening completely Before tightening the screws it is possible to make slight a...

Страница 8: ...s speed is timed to run for 10 minutes At the end of this time the system returns automatically to the speed that was set before If it is activated with the motor turned off the hood will switch to OFF at the end of the time Press and hold for 3 seconds to enable the remote control indicated by the LED flashing twice Press and hold for 3 seconds to disable the remote control indicated by the LED f...

Страница 9: ... once every 2 months use or more frequently if use is particularly intensive CLEANING THE FILTERS Resetting the alarm signal Turn the Lights and the Suction Motor off Press T3 and hold for at least 3 seconds until LED flashes three times in confirmation Cleaning the Filters Remove the Filter pushing it towards the back of the unit and at the same time pulling downward Wash the filter without bendi...

Страница 10: ...e in confirmation CHANGING Resetting the alarm signal Turn the Lights and the Suction Motor off Press T3 and hold for at least 3 seconds until LED flashes three times in confirmation Changing the Filter Remove the Metal Grease Filter Remove the saturated Activated charcoal filter using the hooks provided Fit the new Filter hooking it into place Fit the Grease filter Lighting unit Warning This appl...

Отзывы: