INTRODUCTION
PAPR Respiratory System is a combined face and breathing protection device for increased safety and comfort during welding.
Please read these instructions carefully before unpacking. For proper use, see User Instructions or contact manufacturers for
help.
WARNING AND LIMITATIONS FOR USE
Before each use, inspect the Respiratory System for damage and verify it operates properly. Before using the Respiratory System,
test air flow to verify it is providing an adequate volume of air.
Always wear the Respiratory System and do not remove the head top or turn off the air filter unit until outside the contaminated
area, otherwise, there is a risk of high concentration of CO
2
and oxygen level in the head top will fall, thus little or no protection is
given.
If you are not sure about the concentration of pollution, or about equipment performance, ask the industrial safety engineer.
The manufacturer is not responsible for injury due to the following incorrect use or incorrect choice of
equipment.
Warning:
This respiratory devices should be use with well trained personal and qualified person only.
Before use the devices ensure you are understand that at very high work rates the pressure in the device may become negative at
peak inhalation flow.
Before and during use the devices, attention shall be drawn to possible incorrect use and, where appropriate, the possibility of
looped hoses and/or cables becoming caught up.
Before use or during use the devices if the devices in the power-off state little or no respiratory protection is to be expected, and
that this is considered to be an abnormal situation.
Please leaving the work place and remove the headgear, when the devices in the power-off state a rapid build-up of carbon
dioxide and depletion of oxygen within the hood may occur.
The filters shall only be fitted to the turbo unit and not directly to the helmet/hood.
the user should not confuse the markings on a filter relating to any standard other than EN 12941 with the classification of this
device when used with this filter.
DO NOT use P1000/1003/1004 with the blower unit switched off.
DO NOT use P1000/1003/1004 in an atmosphere that is immediately hazardous to user hygiene or health and/or has oxygen
content of less than 19.5% or contains unknown substances.
DO NOT use P1000/1003/1004 in an explosive atmosphere.
DO NOT use P1000/1003/1004 in confined spaces or areas of poor ventilation
DO NOT use P1000/1003/1004 in high winds.
DO NOT alter or modify in any way.
DO NOT touch any of the moving parts.
DO NOT allow water or other liquids to enter the impeller chamber, the filter or battery compartment.