background image

3

Example 2.   Alarm Output Using Separate 24 VDC Power Supply and Relay. 

Applies to Model AV45 Encoders connector styles “H”, “L”, “P”, “W”

 

ALARM OUTPUT CONNECTION

Avtron AV45 encoders provide an alarm signal if maintenance is required under specific circumstances. Following are application  

examples provided to help install the alarm output. 
Example 1.   Alarm output using +V(OUT). +V(OUT) is equal to +V, the encoder power supply. 

AV45

Remote Alarm

BLACK
RED

GREEN
YELLOW
BLUE
GRAY
ORANGE
WHITE

BROWN
VIOLET

OUTPUT OPTIONS

A
B

D

G

E
H
C

I

F
J

9

4

5

10

2

8

3

7

6

1

+V(OUT)

Z

Z

A
B

B

A

+V

COM

Vcc

OUT

COM

300 OHM

MIN.

GND

FUNCTION

ENCODER

ØB

ØA
ØA

ØB

4-16 VDC SOLID STATE RELAY

Q5
MMFT6661

LINE

DRIVER

NOTE 1

CR8

{

FUNCTIONAL DIAGRAM

50 mA MAXIMUM

“W”

“4” “P”,“Q”,

“Z”

“H”, “L”

ALM

MARKER

MARKER COMPLEMENT

COMMON

+V (Encoder Power)

{

BLACK
RED
GREEN
YELLOW
BLUE
GRAY
ORANGE
WHITE

BROWN
VIOLET

“H”,“L”

OUTPUT OPTIONS

A
B
D

G

E
H
C

I

F

J

9

4

5

10

2

8

3

7

6

1

ALM

+V(OUT)

Z

Z

A
B
B

A

+V

COM

MARKER

MARKER COMPLEMENT

GND

FUNCTION

+V (Encoder Power)

COMMON

24

VDC

RELAY

+

-

POWER

SUPPLY

115 VAC

SINK 100 mA MAXIMUM,

WITHSTAND 50 V MAXIMUM

REFERENCED TO COMMON

Q5
MMFT6661

ENCODER

FUNCTIONAL DIAGRAM

ØB

ØA
ØA

ØB

LINE

DRIVER

NOTE 1

CR8

“W”

“4”

“P”,“Q”,

  “Z”

Содержание AV45 Series

Страница 1: ...hazardous locations which require ATEX UL CUL CSA or other explosion protection cer tification AV45 is not certified for hazardous locations Use XR models for hazardous applications Encoder Instructio...

Страница 2: ...VIN 1 max 15V out VIN 1 VDC Vol Typ 0 5 0 4 0 5 VDC Cable Drive Capacity 1000 5V 500 12V 200 24V 1000 1000 feet Protection Reverse Voltage yes yes yes Short Circuit yes yes yes Transient yes yes yes...

Страница 3: ...ET OUTPUT OPTIONS A B D G E H C I F J 9 4 5 10 2 8 3 7 6 1 V OUT Z Z A B B A V COM Vcc OUT COM 300 OHM MIN GND FUNCTION ENCODER B A A B 4 16 VDC SOLID STATE RELAY Q5 MMFT6661 LINE DRIVER NOTE 1 CR8 FU...

Страница 4: ...F G H 6 PIN MS A A A INCLUDED BUT NOT USED A A INCLUDED BUT NOT USED A A INCLUDED BUT NOT USED D D D CHANNELS CONNECTORS 1 7 OPTIONS T OPTIONS U A A B B Z Z A B B Z Z A A B B Z Z INCLUDED BUT NOT USED...

Страница 5: ...Z Z OPTIONS P V Z OPTIONS R S 10 PIN INDUSTRIAL 10 PIN TWIST LOCK 1 6 2 A F D 1 6 2 D A B A A A A B B Z Z A A B B Z Z OPTIONS P V Z OPTIONS R S 10 PIN INDUSTRIAL 10 PIN TWIST LOCK A A A B B Z Z A A A...

Страница 6: ...mounting bracket kits Option 1 2 or 3 will be re quired for standard installations or replacement of foot mounted Toshi ba TS2113N Hubner HOG OG and FG4 units Read all of the fol lowing instructions a...

Страница 7: ...ch wire pair individually shield ed with braid or foil with drain wire 05 uf of maximum total mutual or direct capacitance outer sheath insulator See specifica tions for maximum cable length Strand ed...

Страница 8: ...standard warranty applies All dimensions are in inches mm B1O FLANGE MOUNT STYLE SHOWN SINGLE OUTPUT CONDUIT BOX 8 04 53 115 1 3 94 100 0 5 0 7 04 178 8 4 25 108 0 6 52 165 6 4 66 118 4 3 25 82 6 2 1...

Страница 9: ...dard warranty applies All dimensions are in inches mm B1O FLANGE MOUNT STYLE SHOWN DUAL OUTPUT M23 CONNECTOR 10 04 53 115 1 0 26 0 6 6 X 6 3 94 100 0 3 35 85 0 4 66 118 4 3 25 82 6 4 24 107 7 6 71 170...

Страница 10: ...imensions are in inches mm TOSHIBA TS2113N FOOT MOUNT STYLE SHOWN P INDUSTRIAL CONNECTOR 18MM SHAFT SUPER MAGNETIC SHIELDING 004 6 00 152 4 8 29 210 5 7 10 180 3 5 90 149 9 4 72 120 0 2 68 68 0 2 80 7...

Страница 11: ...ONNECTOR 11MM SHAFT 1 18 30 0 011 0 0 433 2 68 68 0 6 00 152 4 8 21 208 5 4 52 114 9 0 30 7 5 5 32 135 1 0 35 8 8 1 18 30 0 4 54 115 4 6 88 174 7 1 18 30 0 011 0 0 433 2 03 51 6 2 68 68 0 2 16 54 9 2...

Отзывы: