SPECIFICATIONS
Model:
AVR-G5-B
1
Maximum amplitude
9
:
440 Volts (peak to peak)
Basic waveform:
Bipolar pulse (refer diagrams in this manual)
Pulse width (FWHM):
200 ns to 0.5 s
Load impedance:
≥ 100 kΩ
Output impedance
7
:
50 Ω
Rise, fall times (20%-80%)
7
:
≤ 20 ns
PRF:
1 Hz - 100 kHz
Maximum duty cycle:
80 %
Polarity
3
:
Positive and negative
GPIB and RS-232 control
1
:
Standard on -B units.
LabView Drivers:
http://www.avtechpulse.com/labview
for availability and downloads
Ethernet port, for remote
control using VXI-11.3, ssh,
telnet, web:
Optional
4
. Recommended as a modern alternative to GPIB / RS-232.
See http://www.avtechpulse.com/options/vxi for details.
Settings resolution:
The resolution of the timing parameters (pulse width, delay, period) varies, but is always better
than 0.15% of (|set value| + 20 ns). The amplitude resolution is < 0.1% of the maximum amplitude.
Settings accuracy:
Typically ± 3% (plus ±1V or ± 2 ns) after 10 minute warmup. For high-accuracy applications
requiring traceable calibration, verify the output parameters with a calibrated oscilloscope
10
.
Burst mode:
Optional
8
. Generates 1-500 pulses per trigger event. See
http://www.avtechpulse.com/options/br
Propagation delay:
≤ 100 ns (Ext trig in to pulse out)
Jitter:
± 100 ps ± 0.03% of sync delay (Ext trig in to pulse out)
Trigger modes:
Internal trigger, external trigger (TTL level pulse, > 10 ns, 1 kΩ input impedance), front-panel
“Single Pulse” pushbutton, or single pulse trigger via computer command. In the external trigger
mode, the pulse width may be set by the instrument, or it may be set to track the input pulse width.
Variable delay:
Sync to main out: 0 to 1.0 seconds, for all trigger modes (including external trigger).
Sync output:
> +3 Volts, > 50 ns, will drive 50 Ohm loads
Gate input:
Synchronous or asynchronous, active high or low, switchable. Suppresses triggering when active.
Connectors:
Out, Trig, Sync, Gate: BNC
Power requirements:
100 - 240 Volts, 50 - 60 Hz
Dimensions (H x W x D):
100 mm x 430 mm x 375 mm (3.9” x 17” x 14.8”)
Chassis material:
Aluminum frame and handles, gray vinyl on aluminum cover plates
Rack-mount kit:
Optional. Add -R5 to the model number.
Temperature range:
+5°C to +40°C
1)
-B suffix indicates IEEE-488.2 GPIB and RS-232 control of amplitude, pulse width or duty cycle (as appropriate), pulse repetition frequency, and
delay (See
http://www.avtechpulse.com/gpib
).
2) When triggered externally, the pulse width can be set by the pulse instrument controls, or it may be set to track the input trigger pulse width.
3) Indicate desired polarity by suffixing model number with -P or -N (i.e. positive or negative) or -PN for dual polarity option.
4) Add the suffix -VXI to the model number to specify the Ethernet port.
5) To generate a 0 to ±50V offset internally, add the suffix -OT to the model number. When generating a pulse with positive amplitude, the offset plus
amplitude must remain between 0 and +250V, and when generating a pulse with negative amplitude, the offset plus amplitude must remain between
0 and -250V.
6) This is the resistance in series with the output, internally. The 50 Ohm series resistance provides transmission line back-matching to absorb
reflections from the load. This is not the same as the load impedance. The AVR-G series can not drive 50 Ohm loads.
7) For a non-capacitive load. The 50 Ohm output impedance will cause rise and fall time degradation if the load has capacitance, governed by the RC
time constant.
8) Add the suffix -BR to the model number to specify the burst mode option. See
http://www.avtechpulse.com/options/br
for details about this option. Not
available on the AVR-G5-B model.
9) The minimum useful amplitude is 5% of the maximum amplitude. For lower amplitudes, consider using an external resistor divider.
10)These instruments are provided with a basic calibration checksheet, showing a selection of measured output parameters. These measurements are
performed with equipment that is calibrated on a regular basis by a third-party ISO/IEC 17025:2005 accredited calibration laboratory. However,
Avtech itself does not claim any accreditation. For applications requiring traceable performance, use a calibrated measurement system rather than
relying on the accuracy of the pulse generator settings.
7
Содержание AVR-G5-B
Страница 24: ...Use the correct load impedance 100 k and 100 pF Keep output cable lengths to 2 meters 6 feet or less 24...
Страница 34: ...PCB 158R4 LOW VOLTAGE POWER SUPPLY...
Страница 35: ...PCB 235B HIGH VOLTAGE POWER SUPPLY...
Страница 37: ...PCB 228B OP AMP...
Страница 38: ...PCB 287A TTL BUFFER...
Страница 43: ...PERFORMANCE CHECK SHEET 43...