APPENDIX 2 PIN CONFIGURATION
56
‧
For 4CH Model
Siren:
When the DVR is triggered by alarm or motion, the COM
connects with NO and the siren with strobe starts wailing and
flashing.
Magnetic Contact:
When the magnetic contact is opened, the alarm will be
triggered and the recording is on.
PIN
FUNCTION
DESCRIPTION
1~4
ALARM INPUT
Connect ALARM INPUT (PIN1 – 4) and GND (PIN5) connector with wires. Once an alarm is
triggered, the DVR will start recording and the buzzer will be on.
PIN Alarm
Corresponding
video
channel
PIN 1
1
CH1
PIN 2
2
CH2
PIN 3
3
CH3
PIN 4
4
CH4
*
5
GND GROUND
6
EXTERNAL ALARM COM
Under the normal operation, COM disconnects with NO. But when any alarm is triggered,
COM connects with NO.
Attention: The voltage restriction is under DC24V 1A.
7
EXTERNAL ALARM NO
Under the normal operation, COM disconnects with NO. But when any alarm is triggered,
COM connects with NO.
Attention: The voltage restriction is under DC24V 1A.
8
RS485-A
9
RS485-B
10~11
GND
GROUND