MENU FUNCTION
-28-
The submenu items are described below:
1) TITLE
Show the camera title of each channel set in “CAMERA”.
2) DET
Select if you want to activate the motion detection function for the selected channel (ON/OFF).
3) AREA
Press “ENTER” button to set the detection area. You will see similar screens as the following:
Pink blocks represent the area that is not being detected while the transparent blocks are the area under detection.
Note:
If the connected video output device is LCD monitor, but the “MONITOR OUT” setting in “DISPLAY”
menu is "MAIN", the motion detection area setting will be disabled.
4) LS (Level of Sensitivity)
“LS” is to set the sensitivity of comparing two different images. The smaller the value is, the higher sensitivity for motion
detection.
The highest sensitivity setting is 00, and the lowest sensitivity setting is 15. The default value is 07.
5) SS (Spatial Sensitivity)
“SS” is to set the sensitivity for detecting the size of one object (the number of the grids) on the screen. The smaller the
value is, the higher sensitivity for motion detection.
The highest sensitivity setting is 00, and the lowest sensitivity setting is 15. The default setting is 03.
Note:
The default setting of SS is 03, which means once an object is detected more than 3 grids, the system
will get triggered. So the value of SS must be less than the number of grids that you set up for the
motion detection area.
6) TS (Time of Sensitivity)
“TS” is to set the sensitivity regarding how long one object stays in the detection area and triggers the recording. The
smaller the value is, the higher sensitivity for motion detection.
The highest sensitivity setting is 00, and the lowest sensitivity setting is 15. The default setting is 02.
7) RE (Reference)
“RE” is to set a reference for detection. The default value is 10, which means the DVR will compare 10 continuous
images at one time according to the sensitivity of LS, SS, TS simultaneously.
The bigger the value is, the higher sensitivity for motion detection. The highest sensitivity is 61.
Press “ENTER” to confirm
the start area.
Press “LEFT” or “RIGHT” to
choose the width of the area
Press “UP” or “DOWN” to choose
the height of the area, and press
“ENTER” again to confirm.
You can also up set up
multi-detection areas.
Press “
-
” to set the whole
area under detection
Press “
+
” to set the whole
area undetected