AVS A-SERIES INSTALLATION MANUAL - GEN 2 VER 5
29
Factory remote interface (MAP function)
The AVS A-
Series can be directly controlled using the vehicle’s existing factory remote c
ontrol. By hooking up
the POS1, POS2, NEG1, NEG2, M1 and M2 wires as per most data sheets (either supplied by AVS or not) or by
testing to find the trigger wires, the alarm can be controlled without further programming. The only
programming required is to turn on the interface in
Register 1, Feature 14
and if you require enable mode,
change
Register 1, Feature 10
depending on the vehicle, interface uses inhibit mode as default.
Inhibit mode:
In inhibit mode the alarm will be armed and disarmed by POS1/POS2 and M2/M1 respectively. If a negative
signal is detected by either NEG1 or NEG2, arming or disarming will be inhibited. NEG1 and NEG2 would
normally be hooked up to the negative switch wires from the key barrel or lock/unlock switch in the door or
car. The important thing to remember is that the alarm should only arm and disarm from the factory remote,
not from the key in the door or a switch in the car.
Enable mode:
In enable mode the POS2 wire must see a positive signal to enable the system to arm or disarm. This is often
hooked up to the indicators if they flash on arming or disarming. Please note that with this mode a thief may
be able to turn the hazards on and then press an in-car central locking switch to disarm the alarm. Inhibit
mode is a much more secure upgrade option.
The table below describes each upgrade wires operation:
Wire
Inhibit mode
Enable mode
POS1
Positive arm: arms the alarm when this
wire gets a positive pulse
Positive arm: arms the alarm when this wire gets
a positive pulse and POS2 has a positive feed
POS2
Positive disarm: disarms the alarm when
this wire gets a positive pulse
Positive enable: this wire must go positive, or stay
positive to alarm arm/disarm
NEG1
Negative inhibit: stops arm/disarm
(disables other wires for short period
when this wire gets a negative pulse)
Negative arm: arms the alarm when this wire gets
a negative pulse and POS2 has a positive feed
NEG2
Negative inhibit: stops arm/disarm
(disables other wires for short period
when this wire gets a negative pulse)
Negative disarm: disarms the alarm when this
wire gets a negative pulse and POS2 has a
positive feed
M1
Positive disarm: disarms the alarm when
this wire gets a positive pulse
Positive disarm. Change of state (either negative
to positive or positive to negative) will disarm
alarm when POS2 has a positive feed
M2
Positive arm: arms the alarm when this
wire gets a positive pulse
Positive disarm: Change of state (either negative
to positive or positive to negative) will disarm
alarm. Does
not
require POS2 to have positive
feed
Note: With clip at the top with wires coming towards you, pins from left to right: M1 M2 POS1 POS2 NEG1
NEG2
IMPORTANT: If you are not using the alarm as an upgrade please open the module and unplug and
remove the upgrade loom form the main circuit board.