Dip switch SPIDER PA
LOW
NORMAL
(default)
HIGH
SECURITY
DIP 1 and DIP 2 - SENSITIVITY ADJUSTMENT
Low detection sensitivity. Sensitivity is half than normal, with double pulse
count.
Default sensitivity
Hight detection sensitivity. Sensitivity is like Normal but with single pulse
count.
Spider PA operates as Normal mode, but an alarm is also send when a
single PIR section gives 3 consecutive alarms within 30 seconds.
(default)
Closed contacts alarm output without resistor.
Alarm relay output contacts have a 4K7 Ohm resistor in series
(typical end-of-line resistor of AVS control panels)
DIP 4 - ALARM OUTPUT
DIRECTIONAL AND
AND
(default)
The detector gives an alarm only if, during the 30 seconds intervall
after it has detected an intrusion, the detector connected to AUX
terminals also gives an alarm.
The detector gives an alarm whenever it detects an intrusion while
the other detector is also in alarm.
DIP 3 - AUX INPUT
E
N
G