- 10 -
GENERAL FEATURES
Outdoor self-powered sirens for security systems:
•
City LED Plus with small white ABS container
•
City X LED Plus with small STAINLESS Steel ABS container
•
City CARBON LED Plus with small ABS container with carbon look
•
TS85 P LEDs with white ABS container
•
TS85 V LEDs with white varnished Galvanized iron container
•
TS85 X LEDs in AISI 304 STAINLESS Steel container
-
The
TS85 P/V/X LED
models internally have an independent fastening cover that creates a second obstacle to possible tampering.
-
The unified
ant-removal
system found on all models enables to simultaneously protect against the removal from the wall
and
the opening of the cover and further simplifies assembly operations.
GENERAL FEATURES
Initial blockage
•
The battery can be connected in the absence of power from the control unit,
program and close the cover without activating the Cone. The siren does not
sound until the power supply terminals (+/-) is not connected to the control unit.
Emergency timer
•
If the device that controls the siren is broken, a programmable emergency
timer blocks it
Type of sound modulation
•
It is possible to select from one of the 8 different tones
Alarms Count
•
If programmed, it counts a maximum of 5 alarms in 24 hours
FLASH mode
•
In alarm, it flashes for 40 minutes
•
In alarm, it flashes until the STC comand input is rebalanced
•
In alarm, it flashes until the alarm input is rebalanced
Siren control input (STC)
•
Programmable
Control input (LED)
•
Programmable
Block (B) Input
•
Blocking of the sound in the presence of a positive
FAILURE (FAULT) output
•
Microprocessor block
•
Low level or missing battery
•
Flash fault
•
LED fault
•
Cone fault
•
Cone management circuit fault
TAMPER (T T) output
•
Siren and/or cover anti-removal
•
Anti-vibration
•
Overheating
•
Anti-foam (optional
S85
mode)
Battery polarity inversion
•
The siren is protected against accidental battery polarity inversion
Current limiter
•
All models have a current limiter to avoid the siren from overloading the control
unit.
Autotest
•
FLASH, LED, Cone, Cone management Circuit, Battery periodic check
Level indicator
•
A bubble, inserted inside the container, enables correct installation
AUTOTEST
All models have an autotest system for the following components:
•
LED test: performed periodically.
•
Cone management Circuit test: performed exclusively with siren in alarm state and integrated cone
•
Cone test: performed exclusively with idled siren
•
Battery "dynamic" test: within 15 minutes from the first power supply or at the exit of the programming and, subsequently, at intervals
of approximately 24 hours, the
LEDS and the F
lash are activated simultaneously to verify the correct functioning of the battery.
•
Battery "static" test: a check of the tension value at the ends of the battery is performed periodically by disconnecting the charge
coming from the control unit.
Once all connections and programming are completed and the siren is closed, perform a test of the alarm to test correct
functioning.
The power supply must come from a very low voltage security circuit with the features of a limited power source protected
by a fuse.
E
N
G