23
AV-09-4WL Solar Windsock Light Kit
Maintenance and Servicing
Designed to be maintenance free, the AV-09-4WL requires minimal attention, though the following
maintenance and servicing information is provided to help ensure the life of your Avlite product.
General Maintenance
a. Cleaning Solar Panels
-
Occasional cleaning of the solar panels may be required. Using a cloth and warm soapy water, wipe
off any foreign matter before rinsing the panels with fresh water.
b. Battery Check
-
Inspection of batteries should be performed every three years (minimum) to ensure that the charger,
battery and ancillary electronics are functioning correctly. Using a voltage meter, check that the
battery voltage is at least 12.3 volts under 500MA load, and ensure all terminals are clear of foreign
matter.
Replacing the Battery
a. Disconnect the load
b. Disconnect the solar
c. Unscrew positive and negative leads and remove battery from the battery box
d. Reattach positive and negative leads to new battery
e. Discard old battery in a safe manner.
f.
Reconnect the solar
g. Reconnect the load
h. To test, place dark cover (towel or jacket) on top of light sensor junction box (ref Figure 10) to
activate sensor, light will come on within about 10 seconds.
Follow the instructions for the regulator during assembly. See’Regulator Connection &
Operation’ section of this manual.
Observe the polarity of the battery before the leads are re-connected to ensure the replacement
battery is correctly fitted.