Serial Communication Control
In the default working mode, the camera can connect to a VISCA controller with a RS232C serial
interface.
➢
RS232 Communication Control:
The camera can be controlled via RS232. The parameters of RS232C are as follows:
Bit rate: 2400/4800/9600 bit/s.
Start bit: 1 bit.
Data bit: 8 bits.
Stop bit: 1bit.
Parity bit: none.
➢
RS485 Communication Control:
The camera can be controlled via RS485 in half-duplex mode:
Bit rate: 2400/4800/9600 bit/s.
Start bit: 1 bit.
Data bit: 8 bits.
Stop bit: 1bit.
Parity bit: none.
Pan-Tilt function rotates the camera to its maximum position (towards the top right) upon startup.
It then returns the camera to the center, and the process of initialization is complete. (Note: if there is an
entry for position preset 0, the corresponding position preset 0 will be called up after initialization.)
Then user can control the camera with commands in the command list.
PTZ over TCP/UDP
A TCP server is embedded in camera, port number 5678. When the user establishes a TCP
connection with the server, and sends a PTZ control command to the server, the server will parse and
execute the PTZ command.
A UDP server is embedded in camera, port number 1259. When the user sends a PTZ control
command, the server will parse and execute the PTZ command.
Command List
The serial standard VISCA/ Pelco-D/ Pelco-P needs secondary development. If VISCA/ Pelco-D/
Pelco-P protocol command is needed, please list in detail and contact the manufacturer.