46
compartment and warmer temperature in the lower compartment (example: 5°C upper and 15°C
lower).
•
To select the temperature zone, press (H) once, upper zone will flash, (H) key pressing again to switch
it to lower zone. Setting temperature could only be set under display flash status.
•
You can touch key “+” (C) and key “-” (B) to set the internal temperature for the selected zone. The
degrees indicators will appear in the display window marked for upper zone and for lower zone.
•
When the unit is plugged in for the first time, the LED readouts will show the original temperature set
previously. Touch the “+” (C) and “-” (B) mark once of each compartment to set the desired temperature.
•
The temperature will increase by 1°C or 1ºF if you touch the “+” (C) mark once, or the temperature will
decrease by 1°C or 1ºF if you touch the “-” (B) mark once.
When the surrounding temperature is 25
℃
and the wine cooler has no bottle loaded, it will take around 10
minutes to increase the wine cooler’s temperature from 5
℃
to 12
℃
. Under the same circumstance, it will
take around 20 minutes to decrease the wine cooler’s temperature from 12
℃
to 5
℃
. The less the
temperature span is, the less time it will take. The setting temperature of upper zone should be lower than
the setting temperature of lower zone
Temperature display
Display show at its setting.
To view the actual temperature in either zone at any time, touch key (B) and key (C) for 3 second, the
display will display two zone’s actual temperature with flashing, and it will quit by holding stop.
NOTE:
when first used or after operating the wine cellar after a long period of inactivity, the inner
temperature will not immediately be the temperature setting on the display. Indeed, it is necessary to wait
a few hours for a temperature adjustment of the wine cellar in order to have a homogeneous temperature.
To avoid excessive condensation when the ambient temperature is above 28°C, do not lower the
temperature to below 7°C.
IMPORTANT: after unplugging, turning off the power or after a power failure, it is imperative to wait
5 minutes before turning it on again.
Temperature alarm
The alarm will sound and the temperature display will flash when:
-
The temperature in one of the zones rises or falls outside the temperature range (5-12°C or 12-
20°C)
-
You switch the appliance on, if the temperature inside the appliance is very different (+/- 4°C) from
the temperature set after 7 hours working
-
Too many items have been put into the unit at one time, and the temperature inside the appliance
is very different (+/- 4°C) from the temperature set after 7 hours working
-
The door has not been closed tightly
Door alarm
If the door has been left open for more than 60s, the alarm will sound. Once the set temperature has been
reached in the appliance, the alarm stops and the relevant temperature display stops flashing. However, if
the noise disturbs you, you can switch the alarm off before this if you wish by pressing the key I once. The
alarm will stop. The relevant temperature display continues to flash until the set temperature has been
reached. The display then lights up constantly and the alarm system is fully active again.