EXP5000 Upper Half Display
Entegra EXP5000 PFD
-8-
600-00157-000 Rev. 06
■
The localizer signal has been received.
Or (if used with Garmin 400W/500W navigator)
■
The Nav source is GPS
■
GPS horizontal deviation data has been received
The source of the HDI data is displayed immediately to the right
of the HDI (e.g., LOC, ILS or GPS). If the localizer signal is lost,
the HDI is replaced with a red
X
and the source letters turn red. If
GPS data is lost, the HDI is removed from the display.
To remove the HDI, change either the NAV source or the VOR/
LOC frequency.
10) Altitude Tape
—Displays baro-corrected altitude. The display
range is either:
■
-1,000 feet to 35,000 feet if using air data from the internal
ADAHRS, or
■
-1,000 feet to 53,000 feet if using air data from an external
source.
The box at the top of the tape displays the current value of the Alt
Bug. In general, each minor graduation represents 20 feet and
each 100 foot graduation is labeled. For higher power aircraft,
each minor graduation represents 100 feet and each 500 foot
graduation is labeled. These settings are set by the installer and
may differ for your aircraft.
11) Altitude Window
—Displays the current baro-corrected altitude.
12) Vertical Deviation Indicator (VDI)
—Displays when:
■
The Nav source is VLOC
■
The ILS Glidescope signal has been received
■
The VDI is not displayed for back course localizer
approaches
Or (if used with Garmin 400W/500W navigator)
■
The Nav source is GPS
■
GPS vertical deviation data has been received
To remove the VDI display, change either the NAV Source or the
localizer frequency.
Содержание Envision EXP5000
Страница 1: ...600 00157 000 Rev 06 EXP5000 Primary Flight Display Pilot s Guide ...
Страница 2: ......
Страница 4: ...Entegra EXP5000 PFD ii 600 00157 000 Rev 06 This page intentionally left blank ...
Страница 8: ...Notes and Warnings Entegra EXP5000 PFD 2 600 00157 000 Rev 06 This page intentionally left blank ...
Страница 30: ...EXP5000 Buttons and Knobs Entegra EXP5000 PFD 24 600 00157 000 Rev 06 This page intentionally left blank ...
Страница 80: ...Dual PFD Error Conditions Entegra EXP5000 PFD 74 600 00157 000 Rev 06 This page intentionally left blank ...
Страница 88: ...Entegra EXP5000 PFD 82 600 00157 000 Rev 06 This page intentionally left blank ...
Страница 89: ......