INSTALLATION
Safety guidelines: please refer to the installation manual for all safety instructions.
To install, please download the installation manual from the following webpage: www.avidsen.com/
produits/recherche.php
Overview:
The cables used must be appropriate for outdoor use (such as H07RN-F for example).
The cable run between the two posts must comply with applicable standards (NFC 15-100).
The geared motor power cable must run 80cm deep with red warning mesh.
actuators
Inner side of the property
Flashing light
Switchgear
control unit
1
3
4
2
List of cables:
Connection
Cable
Max length
1
230VAC power line
Cable 3 x 2.5mm2 (more than 30m long)
Cable 3 x 1.5mm2 (less than 30m long)
Unlimited
2
Flashing light
Cable 2 x 0.5mm2
15m
3
Left motor
Cable 2 x 1.5mm²
10m
4
Right motor
Cable 2 x 1.5mm²
10m
The installation is a 4-step process:
1. Installation of the cylinders onto the pillars and gate, and of the electronic panel and flashing light.
2. Electrical connection of the motors, flashing light and electronic panel to the mains. This connection must be performed by qualified personnel
(electrician, etc.).
3. Adjustments and operation:
Warning: Only switch on the electronic panel once all connections have been made.
- Read the installation manual chapter on simple adjustments.
- Launch the movement self-learning programme (press "+" for 3 seconds)
- Programme the remote controls:
- press "-" for 3 seconds
- press "SET"
- press the remote control button to be memorised
- Repeat the operation for each remote control
- Choice of operating mode:
By default, automatic closing is deactivated. To activate it, you must install a pair of photocells (optional)
4. Operational testing: To familiarise yourself with the automatism and ensure its proper operation, read the chapter on usage and conduct operational tests
(opening/closing, initiate obstacle detection, cut the photocell beam (optional). Upon completion of these tests, you may have to modify certain settings (e.g.
motor power).
DECLARATION OF CONFORMITY
avidsen declares that the equipment complies with the essential applicable requirements of RED Directive 2014/53/EU.
Directive 2014/35/EU: (protection of users’ health and safety)
Directive 2014/30/EU: (protection requirements relating to electromagnetic compatibility).
Directive 2014/53/EU: (efficient use of the radio spectrum, in order to avoid harmful interference).
The full declaration of compliance is available on the website www.avidsen.com
Tours, 16/11/2021
Alexandre Chaverot, CEO
Pour en savoir plus :
www.quefairedemesdechets.fr
Avidsen
19 avenue Marcel Dassault - ZAC des Deux Lions - 37200 Tours - France