CTR 8540 GETTING STARTED: INSTALLATION

Health & Safety

Personnel involved with the installation, configuration, or servicing of CTR 8540
must be aware of and comply with the following health and safety requirements.

CAUTION:

For comprehensive health and safety requirements, including

those for installation of radio transceiver options and tower-mounted devices,
refer to the CTR 8540 Installation Guide.

CAUTION:

Local safety regulations must be used if mandatory. Safety

instructions in this guide should be used in addition to the local safety reg-
ulations. Should there be conflict between safety instructions stated in this
guide and those from local regulations, mandatory local norms shall prevail.

Caution Item

Information

Installation and Service Per-
sonnel

Installation and service must be carried out by authorized personnel who

have the technical training and experience necessary to be aware of any haz-
ardous operations during installation and service, and of measures to avoid
any danger to themselves, to any other personnel, and to the equipment.

Service personnel must have received adequate technical training on the

equipment this guide refers to.

Hazardous Materials

No hazardous materials are used in the construction of CTR.

Hazardous Voltage

CTR meets global product safety requirements for safety extra-low voltage
(SELV) rated equipment where the input voltage

must

be 48 V nominal, 57 V

maximum.

Laser and Fiber Optic Cable
Hazards

Any fiber optic transmitters used are IEC60825-1 / 21CFR1040-1 Class I
compliant and present no danger to personnel in normal use. However:

o

Do not look into active unterminated optical ports or fibers. If visual
inspection is required ensure the equipment is turned off or, if a fiber
cable, disconnect the far end.

o

Follow the manufacturer's instructions when using an optical test set.
Incorrect calibration or control settings could result in hazardous
levels of radiation.

o

Protect/cover unconnected optical fiber connectors with dust caps.

o

Place all optical fiber cuttings in a suitable container for safe disposal.
Bare fibers and fiber scraps can easily penetrate the skin and eyes.

Indoor Unit and DC Supply

Grounding

The ground for CTR indoor unit(s) must be connected directly to the dc sup-

ply system ground conductor, or to a bonding jumper from a grounding ter-
minal bar, or bus to which the dc supply system grounding is connected.

Mains Power Supply Routing

CTR dc power, IF, tributary, auxiliary and NMS cables are not to be routed

with any AC mains power lines. They are also to be kept away from any
power lines that cross them.

DC Supply Voltage and Polarity

The CTR main and optional backup (plug-in module) power supply units
have the +ve pin on their d.c. power supply connector connected to chassis
ground. They must be used with a -48 Vdc SELV-compliant power supply
which has a +ve ground; the power supply ground conductor is the +ve
supply to CTR.

12

AVIAT NETWORKS

Содержание CTR 8540

Страница 1: ...CTR 8540 GETTING STARTED Rev 003 December 2014 HARDWARE INSTALLATION 260 668255 001...

Страница 2: ......

Страница 3: ...ce and of measures to avoid any danger to themselves to any other personnel and to the equip ment 2 Access to the Equipment Access to the equipment in use must be restricted to service personnel only...

Страница 4: ...Getting Started Installation 1 Purpose 1 Introduction 1 Unpacking 2 Installation 2 Installation Requirements 3 Installation Procedure 5 Adding Modules to CTR 6 Module Installation Requirements 7 Modul...

Страница 5: ...int a user is expected to make use of the CTR Installation Guide which includes guidance on associated RF units ODUs IRU 600 antennas antenna alignment and much more Introduction CTR 8540 provides in...

Страница 6: ...cal or electrical media l Port trib cables l ODUs or IRU 600 l Antennas l ODU cable kits l Serial cable or serial cable serial USB adapter to provide connection from your PC to the CTR Maintenance V 2...

Страница 7: ...stalled Slot accepts RAC or PoE modules 8 Slot 3 RACx2 module installed Slot accepts RAC or PoE modules 9 4x SFP Switch Ports SFP ports cages SFP transceivers are available for optical or electrical c...

Страница 8: ...ct device main switch Power Supply 24 Vdc An external 24 Vdc to 48 Vdc converter is required at sites using 24 Vdc powering D C Supply Ground Con nection CTR equipment has a connection between the ear...

Страница 9: ...t ground wire path to the rack ground bar 2 Locate the CTR in the equipment rack and secure it using four No 12 Phillips dome head screws from the CTR installation kit 3 Ground the CTR from the ground...

Страница 10: ...tributary cables as required For information on the available tributary cable sets refer to the CTR 8540 Installation Guide 8 Carry out a complete check of the installation When checked and correct o...

Страница 11: ...3000 series all outdoor radios and compliant 3rd party products Figure 1 3 POEx2 Module RACx2 Module Install in any slot to provide two radio interfaces for connection to Aviat ODU 600 ODU 300hp or IR...

Страница 12: ...module ensure its backplane connector is correctly engaged before applying sufficient pressure to bring the module panel flush with the front panel Revision time lag When swapping or installing CTR m...

Страница 13: ...arefully hold the module by its edges and line up the front PCB edges with the guides inside the module slot 5 Insert the module in the slot and gently push in until the front panel of the module is f...

Страница 14: ...ation has been completed with SD card Fan module and option modules fitted l Management access has been prepared To install the power cable 1 Run the supplied power cable through to a dedicated circui...

Страница 15: ...have the transmit mute set as the default unless otherwise specified If frequency and power settings are not correct interference can be caused to other links in the same geographical area CAUTION Al...

Страница 16: ...input voltage must be 48 V nominal 57 V maximum Laser and Fiber Optic Cable Hazards Any fiber optic transmitters used are IEC60825 1 21CFR1040 1 Class I compliant and present no danger to personnel in...

Страница 17: ...ading of a CTR indoor unit or units will not cause any reduction in the mechanical stability of the rack Fan Blades CAUTION Fan card houses hazardous moving parts Restricted Access CTR 8540 must be in...

Страница 18: ......