AVG-UHD4K-44
Command
Function
Feedback
Example
Recall[y].
Recall preset command y,
y=0~11.
Recall From F1
Clear[y].
Clear preset command y, y=0~11.
Clear F1
EDIDG[x].
Get EDID data from output x and
display it on com port.
EDIDM[X]B[y].
Enable input x to learn the EDID
data from output y. If the EDID
data is not available, the matrix
will set it to initial EDID data.
EDIDM3B1
EDIDC[x]B[y].
Capture the EDID data of output x
and save it as No.y EDID, y=1~15
EDIDC3B1
EDIDExtract[x][y].
Recall No.y EDID data saved
through COM port to input x,
y=1~15
Pick up success
UpgradeSoftwareEDID[y].
Save the EDID data to No.y EDID,
recall the EDID by sending
command EDIDExtract[x][y].
Please send the
EDID file
Upgrade success
EDIDUpgrade[x].
Upgrade the EDID data of input x
(x=1~4: upgrade the EDID of
single input; x=9: upgrade the
EDID of all inputs)
Send EDID file (.bin) within 10
seconds.
Please send the
EDID file
Upgrade success
UpgradeIntEDID[x].
Upgrade embedded EDID data
No.x, x=1~10. (Refer to 4.4 EDID
Management
for
detailed
information of embedded EDID
data)
Send EDID file (.bin) within 10
seconds.
Please send the
EDID file