background image

ZM505

Indicator

User Instructions

AWT35-501338

Issue AC

Содержание ZM505

Страница 1: ...ZM505 Indicator User Instructions AWT35 501338 Issue AC...

Страница 2: ...two dimensional work and the making of a copy in two dimensions of a three dimensional work stored in any medium by electronic means or transmitted in any form or by any means including electronic mec...

Страница 3: ...ction 12 Front panel 13 Display 14 Powering up a ZM505 series indicator 15 Using the alphanumeric keypad 15 Entering negative numbers or decimal point 15 Chapter 3 Operator Instructions 16 Power Up 16...

Страница 4: ...4 ZM401 405 Indicator User Instructions Print 30 Chapter 5 Error messages 31 Chapter 6 Supervisor menu 32 Printed Preset Tare report example 33...

Страница 5: ...nction it may be referred to by its alternate function Displayed messages appear in bold italic type and reflect the case of the displayed message Annunciator names appear as italic text and reflect t...

Страница 6: ...tion provided by the socket is suitable for the environment 1 3 Routine maintenance Always isolate the indicator from the power supply before starting any routine maintenance to avoid the possibility...

Страница 7: ...ory to the user Take frequent breaks during prolonged usage 1 6 Sharp objects Do not use sharp objects such as screwdrivers or long fingernails to operate the keys Table 1 1 Cleaning DOs and DON Ts DO...

Страница 8: ...io communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense This...

Страница 9: ...DWLRQ GH O XWLOLVDWLRQ GH FHUWDLQHV VXEVWDQFHV GDQJHUHXVHV GDQV OHV pTXLSHPHQWV pOHFWULTXHV HW pOHFWURQLTXHV 1 8 E 8 RQIRUPLWHLWVYHUNODU LQJ 1DDP HQ DGUHV YDQ GH IDEULNDQW YHU HLJK 7URQL RXQGU DQH 6PH...

Страница 10: ...QJOHWHUUH 6LJQp SDU HW DX QRP GH YHU HLJK 7URQL j UPVWURQJ ULYH DLUPRQW 01 86 OH HWHUW QQRYDWLRQV LUHFWHXU 0DUNHWLQJ E 8 RQIRUPLWHLWVYHUNODU LQJ 0RGHO 7 SH 0 0 5 1DDP HQ DGUHV YDQ GH IDEULNDQW YHU HLJ...

Страница 11: ...OHWHUUH 6LJQp SDU HW DX QRP GH YHU HLJK 7URQL j UPVWURQJ ULYH DLUPRQW 01 86 OH HWHUW QQRYDWLRQV LUHFWHXU 0DUNHWLQJ E 8 RQIRUPLWHLWVYHUNODU LQJ 0RGHO 7 SH 0 0 5 1DDP HQ DGUHV YDQ GH IDEULNDQW YHU HLJK...

Страница 12: ...e indicator requires 100 VAC 240 VAC 50 or 60 Hz or 12 36VDC The standard indicator connectivity includes a USB Host three serial ports and an Ethernet port With an multiple option cards it can suppor...

Страница 13: ...s Press the SELECT key to toggle between the active display values Press and hold to enter the setpoint editor Acts as a down arrow key for menu navigation Allows entry of numeric values Press the PRI...

Страница 14: ...e scale is enabled The SETUP key can be used to perform custom application functions It can also be used to view the password entry screen for menu access The TARGET key can be used to perform custom...

Страница 15: ...the letters starting with upper case and then lower case The decimal key scrolls through the negative sign pound sign colon comma and percent sign The 0 key toggles between 0 and a space 2 4 Entering...

Страница 16: ...uctions for the Accumulation app 3 2 1 Gross weighing To perform gross weighing power up the unit and follow these steps 1 Empty the scale and if necessary press ZERO to zero the display 0 is displaye...

Страница 17: ...ace item to be tared on the scale Weight is displayed 3 Press TARE 0 is displayed and the NET weight is displayed 4 Place material to be weighed into or on the tared item on the scale Net weight of ma...

Страница 18: ...gross weigh mode Using Preset Tare Preset tares are entered in a password protected menu Refer to details described in the Supervisor menu on page 32 There are 10 tare values stored in memory To perfo...

Страница 19: ...oint or output values PRINT key A brief key press or triggering input 3 accumulates and transmits data out serial port 1 See sample below Chan 1 Trans 2 Gross 52 lb Tare 25 lb Net 27 lb Press and hold...

Страница 20: ...ayed value or key in a new value and press ENTER to accept The indicator returns to the normal weighing mode 3 2 4 Performing Accumulation weighments The accumulator application can be used to record...

Страница 21: ...d lists from which you choose one item To help you know where you are in the menu the bargraph at the top of the display is on while the indicator is in the menus and will change appearance according...

Страница 22: ...accept the displayed choice If you choose SAVE no or SAVEYES the indicator exits the menu and returns to normal weighing mode OR If you choose CAnCEL the indicator remains in the menu 4 4 USER level m...

Страница 23: ...his to enter values for the time h x Hour m x Minute s x Seconds User Time Site ID Seal Date Set Style MMDD4Y MMDD2Y DDMM2Y DDMM4Y y x m x d x Set 12hr 12hr AP 24hr Style h x m x s x Archive Port 1 Pr...

Страница 24: ...Month 2 digit Year ddMM4Y Day Month 4 digit Year 4 5 3 Site ID 4 5 4 Seal To exit the menu see Exiting the menus on page 22 Date Set Style MMDD4Y MMDD2Y DDMM2Y DDMM4Y y x m x d x Site ID SitE Use thi...

Страница 25: ...ion X X X XX View Firmware PN AWT30 XXXXX View version X X X XX AWT30 XXXXX X X X XX IP Gateway Subnet Mac 1 xx 2 xx 3 xx 4 xx 5 xx 6 xx 1 xx 2 xx 3 xx 4 xx 1 xx 2 xx 3 xx 4 xx 1 xx 2 xx 3 xx 4 xx Opt...

Страница 26: ...wo parts Press RIGHT arrow key or LEFT arrow key to toggle the display between the first and second parts of the part number VErSion Use this to view the version of the firmware View Firmware PN View...

Страница 27: ...ion card Bus 1 or 2 There are 2 Busses in the ZM505 Card 1 or 2 There can be 2 Cards on each bus in the ZM505 View card description View card version Version Type Bus 1 Card 1 Bus 2 Card 2 Option Enet...

Страница 28: ...enu see Exiting the menus on page 22 To upload a configuration file the license number of the Configurator Ztools software must match one of the license numbers in the indicator Contact AWTX Technical...

Страница 29: ...ned below 4 7 1 Counter Audit Print Counter Config Calib Port 1 Port 2 USB Column Ticket Column Ticket View number of configurations View number of calibrations Counter Config Calib countEr Use this t...

Страница 30: ...olumn or ticket printer Port 2 Under Port 2 choose to print to a column or ticket printer uSb Printing to USB requires that a USB flash drive is connected to the indicator host USB Printing to USB wil...

Страница 31: ...isplay Overload Can t fit on display Underload Can t Entry not in valid range Password entry failed Indicator did not reach a stable zero weight within time window set for automated weighing process B...

Страница 32: ...n the Supervisor menu are described below SuPEr This is the top item in the Supervisor menu tArE This item appears only if Preset Tares are enabled Use this to enter tare weights for up to 10 Preset T...

Страница 33: ...Totals if enabled The message cLr tot will flash on the display Print Select the destination the 200 channel report will be transmitted to Choices are Port 1 Port 2 or USB See a sample report below Ch...

Страница 34: ...34 ZM505 Indicator User Instructions Supervisor menu...

Страница 35: ......

Страница 36: ...A Tel 507 238 4461 Fax 507 238 4195 Email usinfo awtxglobal com www averyweigh tronix com Avery Weigh Tronix UK Foundry Lane Smethwick West Midlands England B66 2LP Tel 44 0 8453 66 77 88 Fax 44 0 121...

Отзывы: