18
RD40RF Remote Display User Instructions
4.
bRD.MPT
Setup when having multiple remotes (ex: RD40RF in both the feedroom and in
the front end loader , communicating back to the indicator on the mixer). All the
RD40RF’s have full access of the functional features of the Model 640.
For proper PT-PT operation the RD40RF and the Model 640 indicator need to
be configured as follows:
RD40RF
Setup the RD40RF for PT-PT and network scale ID 1…10
M640
Setup the Model 640 in the Setup menu. Access the Setup menu
and follow this path in the menu to get to the parameters you need
to set:
640
>
640RF
v
CONF.RF
v
bRD.MPT
. Set up as network
scale ID 1…10.
Networks must match on both the indicator and the RD40RF. So if configured
for network 1, then both products must be configured for network scale ID 1.
4.4 Viewing or Changing the Active RF Channel
The user can select the proper RF channel (scale specific) that the RD40RF will
communicate with, so if there are multiple scales and only one RD40RF the RF channel
is selected and then the weight information from that particular scale is shown on the
RD40RF. This is only applicable in the following modes:
l
Selectable point to point (SPT-PT)
l
Point to Multi-Point (PT-MPT)
4.4.1 View the Active RF
1.
Press the
PRINT/SELECT
key…
Active RF channel is shown (
RF-XX
)
2.
Either press
G/N
to return to weighing mode or after 5-6 seconds will
automatically return to the weighing mode.
4.4.2 Changing the Active RF Channel
1.
Press the
PRINT/SELECT
key…
Active RF channel is shown (
RF-XX
)
2.
Press the
MENU
key several times or press the
RM
key repeatedly until proper
RF
channel is shown…
New channel is shown.
3.
Press
PRINT/SELECT
key…
BUSY