12/03 Rev. 3.00-01
SERVICE MANUAL
General Service
TTX
350
8
Strain relief
Demounting / mounting
1. Remove guard ring (1).
2. Remove strain-relief profile (2) and
springs (3).
Demounting of the axis:
3. Detach back cover.
P
Regarding this point, see the section
"Housing".
4. Take out the mainboard.
P
Regarding this point, see the section
"Printed circuit boards".
5. Loosen the fastening screw (4) of the
axis (hexagon socket).
Tools
-- Hexagon socket, 5 mm
2
1
3
4