background image

 

Содержание Mobile Work Station (MWS) Monarch 9876

Страница 1: ...2007 Avery Dennison Corp All rights reserved 28028 0 Operating Instructions Monarch 9876 and 9878 Mobile Work Station MWS TC987xOI Rev AE 10 19 FUS E...

Страница 2: ...d to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if n...

Страница 3: ...ing Service 1 3 CHARGING THE BATTERIES 2 1 Important Battery Safety Information 2 1 Battery Life 2 2 About the Battery Charger 2 2 Important Charging Information 2 3 Key Switch 2 3 Charger LEDs 2 4 Fr...

Страница 4: ......

Страница 5: ...require some assembly About the 9876 Optional Accessories To assemble the options you may need a 5 32 Hex wrench and a Phillips screw driver The 9876 MWS has combinations of doors and solid panels The...

Страница 6: ...Use the assembly instructions provided with the file folders to assemble folders to the MWS panel 3 Tighten the screws Connecting the Power Cord Connect the charger s power cord to the power inlet Po...

Страница 7: ...nal injury or product damage Caution risk of electrical shock Also known as the High Voltage symbol Audience This manual is designed for the person using the MWS for mobile printing applications After...

Страница 8: ...1 4 Operating Instructions...

Страница 9: ...charge before returning the MWS to use You cannot overcharge the battery The battery charger is intelligent it monitors the battery condition and does not overcharge the lead acid battery Battery life...

Страница 10: ...harged to approximately 75 or better capacity If the CHARGE light does not turn on make sure the charger is properly connected to the batteries and the charger has AC power If the READY light does not...

Страница 11: ...s up to 50 feet or 16 gauge or heavier for lengths up to 100 feet Use of improper extension cord could cause fire and electric shock Use an extension cord bearing the UL listing mark and rated for fou...

Страница 12: ...onment temperature and humidity in your facility or DC Typical conditions are defined as one Monarch printer printing standard compliance 4x6 labels 5 10 minutes of actual printing per hour no auxilia...

Страница 13: ...x 406 mm Operating Limits 40 F to 95 F 5 C to 35 C with thermal transfer supplies 40 F to 95 F 5 C to 35 C with thermal transfer supplies Storage 15 F to 120 F 9 C to 49 C 40 F to 120 F 5 C to 49 C Hu...

Страница 14: ...y the Mobile Work Station and the frequency of use for the equipment Smart charging Note Use only NRTL listed National Recognized Testing Lab accessories Inverters Two inverters are available 700 or 1...

Страница 15: ...24v with 1 000 Inverter 9876 9878 WARNING Only qualified service personnel may install or replace the two 12 volt sealed lead acid batteries used to power the printer on the Station If a battery need...

Страница 16: ...B 2 Operating Instructions 24v with DC to DC Converter 12v 9876...

Страница 17: ...Wiring Diagrams B 3 24v with 700w Inverter 9876 9878...

Страница 18: ...B 4 Operating Instructions 24v with 1 000 Watt Inverter 9876 9878...

Страница 19: ......

Страница 20: ...28028 0 Avery Dennison 170 Monarch Lane Miamisburg OH 45342 1 800 543 6650 In the U S A 1 800 387 4740 In Canada www monarch com...