M09416
®
XLI
®
Thermal Direct Printer
3
Gap/Black Mark
Sensor Calibration,
Label Length
Measurement, Self-
Test
1.Turn off the power switch.
2. Hold on the button then turn on the power switch.
3. Release the button when LED becomes
amber
and blinking.
(Any amber will do during the 5 blinks).
The LED color will be changed as following order.
Amber red (5 blinks)
amber (5 blinks)
green
(5 blinks) green/amber (5 blinks) red/amber (5
blinks) solid green
It calibrates the sensor and measures the label length
and prints internal settings.
Printer
Initialization
1. Turn off the power switch.
2. Hold on the button then turn on the power switch.
3. Release the button when LED turns
green
after 5 amber
blinks.
(Any green will do during the 5 blinks).
The LED color will be changed as following:
Amber red (5 blinks) amber (5 blinks)
green
(5 blinks)
green/amber (5 blinks) red/amber (5
blinks) solid green
Always do
gap/black mark sensor calibration
after
printer initialization.
Force Black Mark
Sensor Calibration
1. Turn off the power switch.
2. Hold on the button then turn on the power switch.
3. Release the button when LED turns
green/amber
after 5
green blinks.
(Any green/amber will do during the 5 blinks).
The LED color will be changed as following:
Amber red (5 blinks) amber (5 blinks) green (5
blinks)
green/amber (5 blinks)
red/amber (5
blinks) solid green
Содержание M09416 XLI
Страница 33: ...M09416 XLI Thermal Direct Printer 30 3 2 Cover Drawing...
Страница 35: ...M09416 XLI Thermal Direct Printer 32 3 4 Main Board Drawing...
Страница 37: ...M09416 XLI Thermal Direct Printer 34 3 6 Top Inner Cover...
Страница 39: ...M09416 XLI Thermal Direct Printer 36 3 8 Lower Inner Cover...
Страница 41: ...M09416 XLI Thermal Direct Printer 38 3 10 Stepping Motor Fixing Assembly...
Страница 43: ...M09416 XLI Thermal Direct Printer 40 3 12 Option Accessories Drawing...
Страница 54: ...M09416 XLI Thermal Direct Printer 51 UPDATE HISTORY Date Content Editor 2 06 2008 First Draft for review TH...
Страница 55: ......