Page 20
Operation
4. Operation
The operator panel allows an easy operation of the machine. There are 4 functions to operate
the machine.
In the service menu, the service technician has the
possibility to configure the labeller according to your
application. This men menu is only for technician and
therefore protected.
4.1
Direct functions
The operator panel has a four-character display and 6 membrane keys. Each key has one
individual function.
Feed
:
Single start for one label.
Display: OKAY
Speed up
:
Higher dispensing speed
Speed down
:
Lower dispensing speed
Display: S02
0
until S55
0
. The last digit is blinking to indicate the fractional
part of the number.
The message S02
0
means 2.0m/min and S55
0
means 55.0m/min.
Position
Î
:
The label position on the product will be moved right.
Position
Í
:
The label position on the product will be moved left.
Display:
010
0
up to 999
9
. The last digit is blinking to indicate the fractional
part of the number.
The message 010
0
means 10.0mm and 999
9
means
999.9mm.
Attention:
The start sensor should be positioned 10-30mm before the
dispensing edge.