Operators Manual
ALS 230
Release 12/07
Page 61
Connections and signals
8.2.3
Signals for the EP applicator
For controlling the applicator the signals air stream, cylinder valve and blow on are necessary.
After a product signal has occurred the labelling cylinder valve is switched active after the delay
STAD. However if at this time the applicator is not in the home position then error message
E__2 is generated. After the delay time APT1 the blow on valve is switched active for the time
APT2.
When APT2 is completed both the labelling cylinder valve and the blow on valve signals are
switched inactive. If the control does not read the home position in the time given - 3* (APT1+
APT2) - than the error message E__2 is generated.
Productstart
Cylinder valve
Dispense label
+ Airstream valve
Blowon valve
Homeswitch
1
2
Missing Label: Labeller not ready for dispense
Error: Applicator not in homeposition
3
Error: Homeposition not detected
STAD
APT1
APT3
APT2
1
3
STAD
STAD
APT1
4 * (APT1 + APT2)
STAD
2
Figure 12 Timing EP applicator
Содержание ALS 230
Страница 1: ...Release 12 07 Artikelnummer 0089999 02...
Страница 2: ......
Страница 12: ......
Страница 18: ...Operators Manual ALS 230 Release 12 07 Page 16 Description...
Страница 45: ...Operators Manual ALS 230 Release 12 07 Page 43 Menu structure...
Страница 46: ......
Страница 60: ...Operators Manual ALS 230 Release 12 07 Page 58 Connections and signals...
Страница 70: ...Operators Manual ALS 230 Release 12 07 Page 68 Connections and signals l Figure 22 Internal I O connector...
Страница 78: ...Operators Manual ALS 230 Release 12 07 Page 76 Errors and warnings...
Страница 84: ......