background image

VID

ALARM

8CH

COM

 

Reference

 

Manual

 

 

6

 

 

PROTOCOL

 

Control

 

code,

 

which

 

send

 

out

 

from

 

DVR

 

       

Command

 

format:

 

9600,N,

 

8,1

 

NO.

 

Function

 

Data1

 

Data2

 

Data3

 

Data4

Data5

Data6

 

Note

 

Format

 

Start

 

bit

 

ID

 

Command

Parameter1

Parameter

 

2

Check

 

sum

 

1

 

Alarm

 

state

 

enquiry

 

E0

 

00

0F

 

3F

 

00

 

00

 

 

 

2

 

Relay

 

state

 

enquiry

 

E0

 

00

0F

 

3B

 

00

 

00

 

 

 

3

 

Output

 

ON/OFF

 

E0

 

00

0F

 

3D

 

B0

B7

 

B8

B15

 

 

Bits

 

(0

15)

 

is

 

the

 

relay

 

control

 

bits

 

of

 

1

16

 

channel,

 

1=ON,

 

0=OFF

 

 
    Data send back 

No.

 

Function

 

Data1

 

Data2

 

Data3

 

Data4

Data5

Note

1

 

Alarm

 

state

 

send

 

back

 

F0

 

00

0F

 

D0

 

A0

A7

A8

A15

A

 

(0

15)

 

is

 

corresponding

 

to

 

alarm

 

inputs

 

1

16,1=alarm,

 

0=dis

alarm

 

2

 

Relay

 

state

 

send

 

back

 

F0

 

00

0F

 

D2

 

A0

A7

A8

A15

A

 

(0

15)

 

is

 

corresponding

 

to

 

outputs

 

1

16,1=ON,

 

0=OFF

 

Note: 

1.The

 

data4&data5

 

of

 

this

 

alarm

 

box

 

is

 

0

 

 

 

NOTES:

 

_____________________________________________________________________________________
_____________________________________________________________________________________
_____________________________________________________________________________________
_____________________________________________________________________________________
_____________________________________________________________________________________
_____________________________________________________________________________________
_____________________________________________________________________________________
_____________________________________________________________________________________

 

Содержание VID-ALARM-8CH-COM

Страница 1: ...or moisture 3 Do not expose to flammable explosive or corrosive gas 4 Avoid exposure to dust or other particles that may get inside the equipment 5 Use of extension cords may significantly increase ri...

Страница 2: ...rew d Power Adapter Additional Items Included Back Panel Front Panel Brief Introduction Alarm in 8 port Normal Open Normal Close Input Voltage 0 15V Alarm out 8 port Normal Open Normal Close connector...

Страница 3: ...channel relay outputs NO Alarm linkage function Watchdog function auto reset function in strong reference environment Open circuit and short circuit arm function Provide protocol 16 ID setting connec...

Страница 4: ...dance with the host computer protocol 6 Connection Operate as following figure to connect alarm probe and connect a resistance 2K in series connection at NO contact S signal ground wire 7 Protocol set...

Страница 5: ...ing please refers to the table below The number 1 means the DIP switch setting should be ON and the number 0 means OFF Note the ID number is binary digit ID Switch number 1 2 3 4 0 0 0 0 0 1 0 0 0 1 2...

Страница 6: ...0 0F D2 A0 A7 A8 A15 A 0 15 is corresponding to outputs 1 16 1 ON 0 OFF Note 1 The data4 data5 of this alarm box is 0 NOTES ____________________________________________________________________________...

Страница 7: ...be certain to have full details about your Aventura products available including model and invoice numbers Service Any service required by this unit should be performed by Aventura or authorized servi...

Отзывы: