background image

VID

ALARM

8CH

COM

 

Reference

 

Manual

 

 

5

 

 

8.Setting

 

the

 

alarm

 

box

 

ID

 

The

 

alarm

 

box

 

ID

 

number

 

is

 

set

 

by

 

setting

 

the

 

1

4

 

bits

 

of

 

DIPswitch.

 

Detailed

 

setting

 

please

 

refers

 

to

 

the

 

table

 

below.

 

The

 

number

 

1

 

means

 

the

 

DIP

 

switch

 

setting

 

should

 

be

 

“ON”,

 

and

 

the

 

number

 

0

 

means

 

“OFF”.

 

Note:

 

the

 

ID

 

number

 

is

 

binary

 

digit

 

ID

 

Switch

 

number

 

1

 

2

 

3

 

4

 

0

 

0

 

0

 

0

 

0

 

1

 

0

 

0

 

0

 

1

 

2

 

0

 

0

 

1

 

0

 

3

 

0

 

0

 

1

 

1

 

4

 

0

 

1

 

0

 

0

 

5

 

0

 

1

 

0

 

1

 

6

 

0

 

1

 

1

 

0

 

7

 

0

 

1

 

1

 

1

 

8

 

1

 

0

 

0

 

0

 

9

 

1

 

0

 

0

 

1

 

10

 

1

 

0

 

1

 

0

 

11

 

1

 

0

 

1

 

1

 

12

 

1

 

1

 

0

 

0

 

13

 

1

 

1

 

0

 

1

 

14

 

1

 

1

 

1

 

0

 

15

 

1

 

1

 

1

 

1

 

 

 

Содержание VID-ALARM-8CH-COM

Страница 1: ...or moisture 3 Do not expose to flammable explosive or corrosive gas 4 Avoid exposure to dust or other particles that may get inside the equipment 5 Use of extension cords may significantly increase ri...

Страница 2: ...rew d Power Adapter Additional Items Included Back Panel Front Panel Brief Introduction Alarm in 8 port Normal Open Normal Close Input Voltage 0 15V Alarm out 8 port Normal Open Normal Close connector...

Страница 3: ...channel relay outputs NO Alarm linkage function Watchdog function auto reset function in strong reference environment Open circuit and short circuit arm function Provide protocol 16 ID setting connec...

Страница 4: ...dance with the host computer protocol 6 Connection Operate as following figure to connect alarm probe and connect a resistance 2K in series connection at NO contact S signal ground wire 7 Protocol set...

Страница 5: ...ing please refers to the table below The number 1 means the DIP switch setting should be ON and the number 0 means OFF Note the ID number is binary digit ID Switch number 1 2 3 4 0 0 0 0 0 1 0 0 0 1 2...

Страница 6: ...0 0F D2 A0 A7 A8 A15 A 0 15 is corresponding to outputs 1 16 1 ON 0 OFF Note 1 The data4 data5 of this alarm box is 0 NOTES ____________________________________________________________________________...

Страница 7: ...be certain to have full details about your Aventura products available including model and invoice numbers Service Any service required by this unit should be performed by Aventura or authorized servi...

Отзывы: