“PD” Relay Valve 

Service Information 

 

SM-400.8004 

The “PD” Relay Valve reduces the required capacity 
and size of the control lines. The relay valve also 
eliminates the delay normally caused by exhausting 
the air back through long lines.  

WARNING: INSTALLATION and MOUNTING 

 

The user of these devices must conform to 

all applicable electrical, mechanical, piping and other 
codes in the installation, operation or repair of these 
devices.  

INSTALLATION!   Do not attempt to install, oper-
ate or repair these devices without proper train-
ing in the technique of working on pneumatic or 
hydraulic systems and devices, unless under 
trained supervision. Compressed air and hydrau-
lic systems contain high levels of stored energy. 
Do not attempt to connect, disconnect or repair 
these products when a system is under pressure. 
Always exhaust or drain the pressure from a sys-
tem before performing any service work. Failure 
to do so can result in serious personal injury. 
MOUNTING! Devices should be mounted and 
positioned in such a man

n

er that they cannot be

accidentally operated. 

 

The “PD” Relay Valve functions to relay or repeat con-
trol pressure signals with large quantities of air at cor-
responding pressures. Used in systems where long 
lines are required from the control device to the receiv-
ing device, the PD4 Relay Valve permits fast system 
response by reducing control pressure transmission 
times. A direct local connection is made possible, 
through the Relay Valve, between a supply source and 
the receiving device. This reduces the required capac-
ity and size of the controlling device and the size of the 
control line. When control pressure is reduced or re-
leased, a local exhaust of pressure from the receiving 

device, through the Relay Valve, eliminates the delay 
normally caused by exhausting the air back through 
the long control line.  

CONSTRUCTION 

The  “PD”  Relay  Valve  is  corrosion  resistant  with  an 
anodized aluminum valve body and operator castings. 
The  balanced  spool  valve  is  stainless  steel.    Triple 
supported,  oil-resistant  seals  give  a  tight  closure  and 
long life protection. The large spring-opposed piston is 
also  cast  aluminum  and  has  an  “O”  ring  seal.    The 
spring and various other parts are cadmium plated.  

OPERATION 

 

Control pressures applied to the top of the control piston 
positions a spool valve to allow inlet pressure to flow to the 
outlet port. This outlet pressure, in addition to flowing to 
the receiving device, flows to the underside of the control 
piston through the external copper tubing connection.  
When the outlet pressure balances the applied control 
pressure, the spool valve is returned by a spring to close 
the connection between inlet and outlet.  Air pressure re-
quirements of the receiving device automatically cause the 
control piston to function to maintain pressure in the outlet 
line, either increasing or decreasing to an amount corre-
sponding to the control pressure, under varying operating 
conditions. 

 

Содержание PD-4

Страница 1: ...sure transmission times A direct local connection is made possible through the Relay Valve between a supply source and the receiving device This reduces the required capac ity and size of the controlling device and the size of the control line When control pressure is reduced or re leased a local exhaust of pressure from the receiving device through the Relay Valve eliminates the delay normally ca...

Страница 2: ...ow from outlet to exhaust project from the OUTLET PRESSURE scale to the dash line curve and then to the left SENSITIVITY As shown by the graph below the outlet pressure follows very closely the control pressure throughout the control range The tabula tion shown indicates the changes in outlet pressure required to operate the valve and restore the speci fied outlet pressure ORDERING REFERENCE 1 2 P...

Страница 3: ...Page 3 Exploded View ...

Страница 4: ...00000 Front Cover 1 14 See kit See kit Packing Ring 3 15 See kit See kit Packing Seal 4 16 R431001052 P 030305 00000 Body Segment 1 17 R431001114 P 030781 00000 Body Segement 1 18 See kit See kit Stem 1 19 R431002578 P 049985 00001 TIE ROD 1 4 20 NC 2A X 5 4 20 R431002687 P 050614 00000 Back Cover 1 21 R431002670 P 050570 00000 MOUNTING ADAPTER NUT D PILOTAIR 4 22 R431007527 P 069975 00000 SPRING ...

Страница 5: ...tenance periods should be scheduled in accordance with frequency of use and working conditions All AVENTICS products should provide a minimum of 1 000 000 cycles of maintenance free service when used and lubricated as recommended However these products should be visually inspected for defects and given an in system operating performance and leakage test once a year Where devices require a major re...

Страница 6: ...tan Ontario CANAD A L71tt TM www av entics cam ca infa ca a11entics cam Slv1 4QQ 8QQ4 May 2QT4 Sub1ec ttn c hange Printed in Unite ct States AVENTICS Carparatian This dac urnent as well as the data spec ific atians and atherinfurmatian setfurth in it are the ED Clusive property atAVEl JTICS It may natb e repraduc ed argiven ta third parties withautits c ansent ...

Отзывы: