OPERATION

FOR YOUR SAFETY READ BEFORE LIGHTING

 WARNING: If you do not fol-

low these instructions exactly, a 

fire or  explosion may result caus-

ing property damage, personal 

injury or loss of life.

A.  This appliance has a pilot which must 

be lighted by hand. When lighting the 

pilot, follow these instructions exactly.

B.  BEFORE  LIGHTING  smell  all  around 

the appliance area for gas. Be sure to 

smell next to the floor because some 

gas is heavier than air and will settle 

on the floor.

 

WHAT TO DO IF YOU SMELL GAS

• Do not try to light any appliance.

• Do not touch any electric switch; do 

not use any phone in your building.

• Immediately  call  your  gas  supplier 

from a neighbor’s phone. Follow the 

gas supplier’s instructions.

• If you cannot reach your gas supplier, 

call the fire department.

C.  Use only your hand to push in or turn 

the gas control knob. Never use tools. 

If  the  knob  will  not  push  in  or  turn 

by  hand,  don’t  try  to  repair  it,  call  a 

qualified service technician. Force or 

attempted repair may result in a fire or 

explosion.

D.  Do not use this appliance if any part 

has been under water. Immediately call 

a qualified service technician to inspect 

the appliance and to replace any part of 

the control system and any gas control 

which has been under water.

1.  STOP!  Read  the  safety  information 

above.

2.  Make sure equipment shutoff valve is fully 

open.

3.  Turn control knob clockwise 

 to the 

OFF position.

4.  Wait five (5) minutes to clear out any air. 

Then  smell  for  gas,  including  near  the 

floor. If you smell gas, STOP! Follow "B" 

in the safety information above. If you do 

not smell gas, go to the next step.

5.  Turn control knob counterclockwise 

 

to  the  PILOT  position.  Press  in  control 

knob for five (5) seconds (see Figure 21).

 

Note: The first time that the heater is oper-

ated after connecting the gas supply,the 

control knob should be pressed for about 

thirty (30) seconds. This will allow air to 

bleed from the gas system. If pilot does 

not stay lit, refer to Troubleshooting, pages 

23  though  26. Also  contact  a  qualified 

service technician or gas supplier for 

repairs. Until repairs are made, light pilot 

with match.

• If  control  knob  does  not  pop  up  when 

released,  contact  a  qualified  service 

technician or gas supplier for repairs.

LIGHTING INSTRUCTIONS

6.  With  control  knob  pressed  in,  push 

down  and  release  ignitor  button.  This 

will  light  pilot.  The  pilot  is  attached  to 

the  front  of  burner.  The  pilot  can  be 

seen  through  the  grill.  If  needed,  keep 

pressing  ignitor  button  until  pilot  lights.

 

Note: If pilot does not stay lit, refer to 

Troubleshooting, pages 23 though 26. 

Also contact a qualified service technician 

or gas supplier for repairs. Until repairs 

are made, light pilot with match. To light 

pilot with match, see Manual Lighting 

Procedure

, page 19

.

OF

F  

  PI

LO

Figure 21 - Control Knob in the OFF 

Position

Ignitor 

Button

Control 

Knob

Содержание FDT10BF

Страница 1: ...ical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire...

Страница 2: ...this manual WARNING Improper installation adjustment al teration service or maintenance can cause injury or property damage Refer to this manual for correct in stallation and operational procedures F...

Страница 3: ...le are more af fected by carbon monoxide than others These include pregnant women people with heart or lung disease or anemia those under the influ ence of alcohol and those at high altitudes NATURALA...

Страница 4: ...ucts may create a white powder residue within burner box or on adjacent walls or furniture 8 Do not use heater if any part has been under water Immediately call a qualified service technician to insp...

Страница 5: ...6 x 12 2 Carton Dimensions HxWxD 22 83 x 17 95 x 8 23 26 18 x 20 7 x 9 84 Heater Weight 16 5 lbs 22 lbs Shipping Weight 19 4 lbs 26 7 lbs Model FDT30BF Ignition Piezo Ignitor Gas Type Natural Gas Prop...

Страница 6: ...ay New York NY 10018 National Fire Protection Association Inc 1 Batterymarch Park Quincy MA 02269 9101 This heater is designed for vent free op eration State and local codes in some areas prohibit the...

Страница 7: ...quate combustion and ventilation air Read the following instructionstoinsureproperfresh air for this and other fuel burning appliances in your home Today s homes are built more energy efficient than e...

Страница 8: ...or into adjoining room see option 3 Figure 2 Follow the National Fuel Gas Code ANSI Z223 1 NFPA 54 Air for Combustion and Ventilation for required size of ventilation grills or ducts Ventilation Air F...

Страница 9: ...or Figure 4 Mounting Clearances as Viewed From Front of Heater IMPORTANT Vent free heaters add moisture to the air Although this is beneficial installing heater in rooms without enough ventilation air...

Страница 10: ...n taped there for shipping Remove mounting bracket from back panel Methods For Attaching Mounting Bracket To Wall Use only the last hole on each end of mount ing bracket to attach bracket to wall Atta...

Страница 11: ...ing bracket is firmly fastened to wall studs Attaching to Wall Anchor Method For attaching mounting bracket to hollow walls wall areas between studs or solid walls concrete or masonry 1 Drill holes at...

Страница 12: ...Installing Bottom Mounting Screws Installing Wall Spacers 1 Place heater on wall mounting bracket 2 Mark screw locations on wall 3 Remove heater from mounting bracket 4 If installing bottom mounting...

Страница 13: ...let of regulator a qualified installer or service technician must use supplied cap You will notice a color coded plungerontheinsideoftheregu lator Thisisnormal Whenthein let connection fitting is inse...

Страница 14: ...s on the connection fitting While pushing in rotate the fitting clockwise until the threads engage the regulator After the fitting has been hand tightened into the regulator use a wrench to complete t...

Страница 15: ...egulator between the heater and gassupply Gassupplierprovides externalregulatorfornaturalgas Theinstallerprovidestheexternal regulator for propane LP gas CAUTION Avoid damage to regulator Hold gas reg...

Страница 16: ...Regulator with Vent Pointing Down Propane LP Supply Tank Equipment Shutoff Valve Ground Joint Union 3 8 NPT Pipe Nipple Tee Joint Reducer Bushing to 1 8 NPT 1 8 NPT Plug Tap Test Gauge Connection Sed...

Страница 17: ...ECTIONS 5 Correct all leaks at once 6 Light heater see Lighting Instructions on page 18 Check all other internal joints for leaks 7 Turn off heater see To Turn Off Gas Ap pliance page 19 1 Open equipm...

Страница 18: ...ove 2 Make sure equipment shutoff valve is fully open 3 Turn control knob clockwise to the OFF position 4 Wait five 5 minutes to clear out any air Then smell for gas including near the floor If you sm...

Страница 19: ...ch Hold match to pilot until pilot lights 7 Keep control knob pressed in for 30 sec onds after lighting pilot After 30 seconds release control knob If control knob does not pop up when released contac...

Страница 20: ...ed Electrical Outlet ELECTRICAL WIRING Any electrical re wiring of this appliance must be done by a qualified electrician This wiring must be done in accordance with local codes and or in Canada with...

Страница 21: ...ool which shuts the heater off If pilot flame pattern is incorrect as shown in Figure 25 turn heater off see To Turn Off Gas to Ap pliance page 19 see Troubleshooting pages 23 through 26 WARNING If ye...

Страница 22: ...rty minutes 2 Remove four screws securing front panel 3 Pull front panel forward 4 Inspect burner and pilot for dust and dirt 5 Blow air through the ports slots and holes in the burner 6 Replace front...

Страница 23: ...ust as well as the fan heater is recommended For heavy or continuous use periodic cleaning must be done more frequently If the heater blows alternating cold and warm air check the fan for free movemen...

Страница 24: ...ilot is clogged 5 Incorrectinletgaspressureorin let regulator setting is damaged 6 Control knob not in PILOT position 7 Depleted gas supply pro pane 1 Turn on gas supply or open equipment shutoff valv...

Страница 25: ...ll 3 Inlet gas pressure is too low 1 Clean burner orifice see Care and Maintenance page 22 or replace burner orifice 2 Replace burner orifice 3 Contact local gas supplier Delayed ignition of burner s...

Страница 26: ...wax carpet cleaners etc turn into white powder residue 1 Turn heater off when using furniture polish wax carpet cleaner or similar products Heater produces un wanted odors 1 Heater is burning vapors...

Страница 27: ...have your model and serial numbers of your heater ready REPLACEMENT PARTS Note Use only original replacement parts This will protect your warranty coverage for parts replaced under warranty PARTS UND...

Страница 28: ...www factorybuysdirect com 200264 01B 28 PARTS MODEL FDT10BF 2 10 3 1 8 7 5 6 9 13 12 11 4...

Страница 29: ...MB060 02 Mounting Bracket 1 3 ML083 04 Piezo Ignitor 1 4 STL1001 Thermostat Valve Assembly 1 5 Burner Assembly 1 6 ND0310A MU 600 PI4 ODS Pilot 1 7 RVD88 UB 4 9 Safety Dual Fuel Regulator 1 8 160960 0...

Страница 30: ...www factorybuysdirect com 200264 01B 30 PARTS MODELS FDT20BF AND FDT30BF 10 2 11 3 1 8 7 5 6 9 14 13 12 15 16 4...

Страница 31: ...Assembly 1 5 Burner Assembly 1 6 ND0310A MU 800 PI6 ND0310A MU 800 PI6 ODS Pilot 1 7 RVD88 MAB 4 9 RVD88 MAB 4 9 Safety Dual Fuel Regulator 1 8 160960 01 160960 01 Cap with Seal 1 9 160960 02 160960 0...

Страница 32: ...st of part s required to restore this product to proper operating condition and an allowance for labor when provided by a Factory Buys Direct Authorized Service Center or a provider ap proved by Facto...

Отзывы: