INSTALLATION

as shown in Figure 17. Pointing the vent down 

protects it from freezing rain or sleet.
Install sediment trap in supply line as shown 

in Figure 16. Place sediment trap where it is 

within reach for cleaning. Place sediment trap 

where trapped matter is not likely to freeze. 

A sediment trap traps moisture and contami-

nants. This keeps them from going into heater 

controls. If sediment trap is not installed or is 

installed wrong, heater may not run properly.

Figure 16 - Gas Connection

* Purchase the optional CSA design-certified equipment 

shutoff valve from your dealer.

Apply pipe joint sealant lightly to male threads. 

This will prevent excess sealant from going 

into pipe. Excess sealant in pipe could result 

in clogged heater valves.
The installer must supply an external regula-

tor. The external regulator will reduce incom-

ing gas pressure. You must reduce incoming 

gas pressure to between 11" and 14" of water. 

If you do not reduce incoming gas pressure, 

heater regulator damage could occur. Install 

external regulator with the vent pointing down 

Figure 17 - External Regulator 

with Vent Pointing Down

External 

Regulator with 

Vent Pointing 

Down

Propane/LP 

Supply Tank

Equipment 

Shutoff Valve

Ground 

Joint Union

3/8" NPT 

Pipe Nipple

Tee Joint

Reducer 

Bushing to 

1/8" NPT

1/8" NPT 

Plug Tap

Test Gauge 

Connection*

Sediment 

Trap

Tee Joint

Pipe Nipple

Gap

3" Minimum

Natural Gas

From Gas Meter

 

(5" W.C.** to 9" W.C. 

Pressure)

Propane/LP 

From External 

Regulator (11" 

W.C.** to 14" W.C. 

Pressure)

CHECKING GAS CONNECTIONS

1.  Disconnect heater with its appliance main 

gas valve (control valve) and equipment 

shutoff valve from gas supply piping sys-

tem. Pressures in excess of 1/2 PSIG will 

damage heater regulator.

2.  Cap off open end of gas pipe where equip-

ment shutoff valve was connected.

3.  Pressurize supply piping system by either 

using compressed air or opening gas sup-

ply valve.

 WARNING: Test all gas piping 

and connections for leaks after 

installing or servicing. Correct 

all leaks at once.

 WARNING: Never use an open 

flame to check for a leak. Apply a 

mixture of liquid soap and water 

to all joints. If bubbles form, there 

is a leak. Correct all leaks at once.

PRESSURE TESTING GAS SUPPLY PIPING SYSTEM

Test Pressures In Excess Of 1/2 PSIG (3.5 kPa)

4.  Check  all  joints  of  gas  supply  piping 

system. Apply mixture of liquid soap and 

water to gas joints. If bubbles form, there 

may be a leak.

5.  Correct all leaks at once.
6.  Reconnect heater and equipment shutoff 

valve to gas supply. Check reconnected 

fittings for leaks.

Содержание FDT10BF

Страница 1: ...ical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire...

Страница 2: ...this manual WARNING Improper installation adjustment al teration service or maintenance can cause injury or property damage Refer to this manual for correct in stallation and operational procedures F...

Страница 3: ...le are more af fected by carbon monoxide than others These include pregnant women people with heart or lung disease or anemia those under the influ ence of alcohol and those at high altitudes NATURALA...

Страница 4: ...ucts may create a white powder residue within burner box or on adjacent walls or furniture 8 Do not use heater if any part has been under water Immediately call a qualified service technician to insp...

Страница 5: ...6 x 12 2 Carton Dimensions HxWxD 22 83 x 17 95 x 8 23 26 18 x 20 7 x 9 84 Heater Weight 16 5 lbs 22 lbs Shipping Weight 19 4 lbs 26 7 lbs Model FDT30BF Ignition Piezo Ignitor Gas Type Natural Gas Prop...

Страница 6: ...ay New York NY 10018 National Fire Protection Association Inc 1 Batterymarch Park Quincy MA 02269 9101 This heater is designed for vent free op eration State and local codes in some areas prohibit the...

Страница 7: ...quate combustion and ventilation air Read the following instructionstoinsureproperfresh air for this and other fuel burning appliances in your home Today s homes are built more energy efficient than e...

Страница 8: ...or into adjoining room see option 3 Figure 2 Follow the National Fuel Gas Code ANSI Z223 1 NFPA 54 Air for Combustion and Ventilation for required size of ventilation grills or ducts Ventilation Air F...

Страница 9: ...or Figure 4 Mounting Clearances as Viewed From Front of Heater IMPORTANT Vent free heaters add moisture to the air Although this is beneficial installing heater in rooms without enough ventilation air...

Страница 10: ...n taped there for shipping Remove mounting bracket from back panel Methods For Attaching Mounting Bracket To Wall Use only the last hole on each end of mount ing bracket to attach bracket to wall Atta...

Страница 11: ...ing bracket is firmly fastened to wall studs Attaching to Wall Anchor Method For attaching mounting bracket to hollow walls wall areas between studs or solid walls concrete or masonry 1 Drill holes at...

Страница 12: ...Installing Bottom Mounting Screws Installing Wall Spacers 1 Place heater on wall mounting bracket 2 Mark screw locations on wall 3 Remove heater from mounting bracket 4 If installing bottom mounting...

Страница 13: ...let of regulator a qualified installer or service technician must use supplied cap You will notice a color coded plungerontheinsideoftheregu lator Thisisnormal Whenthein let connection fitting is inse...

Страница 14: ...s on the connection fitting While pushing in rotate the fitting clockwise until the threads engage the regulator After the fitting has been hand tightened into the regulator use a wrench to complete t...

Страница 15: ...egulator between the heater and gassupply Gassupplierprovides externalregulatorfornaturalgas Theinstallerprovidestheexternal regulator for propane LP gas CAUTION Avoid damage to regulator Hold gas reg...

Страница 16: ...Regulator with Vent Pointing Down Propane LP Supply Tank Equipment Shutoff Valve Ground Joint Union 3 8 NPT Pipe Nipple Tee Joint Reducer Bushing to 1 8 NPT 1 8 NPT Plug Tap Test Gauge Connection Sed...

Страница 17: ...ECTIONS 5 Correct all leaks at once 6 Light heater see Lighting Instructions on page 18 Check all other internal joints for leaks 7 Turn off heater see To Turn Off Gas Ap pliance page 19 1 Open equipm...

Страница 18: ...ove 2 Make sure equipment shutoff valve is fully open 3 Turn control knob clockwise to the OFF position 4 Wait five 5 minutes to clear out any air Then smell for gas including near the floor If you sm...

Страница 19: ...ch Hold match to pilot until pilot lights 7 Keep control knob pressed in for 30 sec onds after lighting pilot After 30 seconds release control knob If control knob does not pop up when released contac...

Страница 20: ...ed Electrical Outlet ELECTRICAL WIRING Any electrical re wiring of this appliance must be done by a qualified electrician This wiring must be done in accordance with local codes and or in Canada with...

Страница 21: ...ool which shuts the heater off If pilot flame pattern is incorrect as shown in Figure 25 turn heater off see To Turn Off Gas to Ap pliance page 19 see Troubleshooting pages 23 through 26 WARNING If ye...

Страница 22: ...rty minutes 2 Remove four screws securing front panel 3 Pull front panel forward 4 Inspect burner and pilot for dust and dirt 5 Blow air through the ports slots and holes in the burner 6 Replace front...

Страница 23: ...ust as well as the fan heater is recommended For heavy or continuous use periodic cleaning must be done more frequently If the heater blows alternating cold and warm air check the fan for free movemen...

Страница 24: ...ilot is clogged 5 Incorrectinletgaspressureorin let regulator setting is damaged 6 Control knob not in PILOT position 7 Depleted gas supply pro pane 1 Turn on gas supply or open equipment shutoff valv...

Страница 25: ...ll 3 Inlet gas pressure is too low 1 Clean burner orifice see Care and Maintenance page 22 or replace burner orifice 2 Replace burner orifice 3 Contact local gas supplier Delayed ignition of burner s...

Страница 26: ...wax carpet cleaners etc turn into white powder residue 1 Turn heater off when using furniture polish wax carpet cleaner or similar products Heater produces un wanted odors 1 Heater is burning vapors...

Страница 27: ...have your model and serial numbers of your heater ready REPLACEMENT PARTS Note Use only original replacement parts This will protect your warranty coverage for parts replaced under warranty PARTS UND...

Страница 28: ...www factorybuysdirect com 200264 01B 28 PARTS MODEL FDT10BF 2 10 3 1 8 7 5 6 9 13 12 11 4...

Страница 29: ...MB060 02 Mounting Bracket 1 3 ML083 04 Piezo Ignitor 1 4 STL1001 Thermostat Valve Assembly 1 5 Burner Assembly 1 6 ND0310A MU 600 PI4 ODS Pilot 1 7 RVD88 UB 4 9 Safety Dual Fuel Regulator 1 8 160960 0...

Страница 30: ...www factorybuysdirect com 200264 01B 30 PARTS MODELS FDT20BF AND FDT30BF 10 2 11 3 1 8 7 5 6 9 14 13 12 15 16 4...

Страница 31: ...Assembly 1 5 Burner Assembly 1 6 ND0310A MU 800 PI6 ND0310A MU 800 PI6 ODS Pilot 1 7 RVD88 MAB 4 9 RVD88 MAB 4 9 Safety Dual Fuel Regulator 1 8 160960 01 160960 01 Cap with Seal 1 9 160960 02 160960 0...

Страница 32: ...st of part s required to restore this product to proper operating condition and an allowance for labor when provided by a Factory Buys Direct Authorized Service Center or a provider ap proved by Facto...

Отзывы: