PET IMMUNITY
If there is the possibility of transit of pets in the protected zone,
use the Blinding’s lens provided by applying it* on the lens so as
to leave uncovered only the two upper zones.
The result is it in the figure below.
TIPS FOR INSTALLATION
In indoor installations, prefer placement of the sensor toward the
inside of the room and away from operating machinery and heat
sources. Avoid to direct it toward the windows exposed to the
sunny. In outdoor installations, prevent that the sun’s rays, es-
pecially during the hottest hours of the day, come directly to the
infrared sensing element.
Aplication of Blinding’s lens
Remove the lens blocker by unscrewing the screws A and B.
Remove the lens and apply the adhesive “Blinding’s lens” leaving
uncovered only the two highest zones.
Refit the lens and the lens blocker by doing the reverse procedure.
SETTING
Through the positioning of the 5 Dip Switches is possible to adapt
the sensor working to the your installing needs.
* Note: Depending on your needs, you can make a different
partitioning of the areas of the infrared detection by cutting
appropriately the Blinding’s lens and leaving uncovered other
zones of the the lens
DIP SWITCH
1 GLOBAL MASK IR + MW
ON = ACTIVED
OFF = DEACTIVATED
2 OUTDOOR / INDOOR
ON = INDOOR
OFF = OUTDOOR
3 CROSSING / APPROACH
ON = APPROACH
OFF = CROSSING
4 MW ANTIMASK
DEACTIVATION
ON = DEACTIVED
OFF= ACTIVATED
5 LED OFF
ON = LED OFF
OFF = LED ON
GLOBAL ANTIMASK
- Total Antimask MW + IR
DipSwitch N°1 in pos. ON
and Plastic Front closed
Any element that can mask
the MW or the lens of the
IR generates an alarm dis-
played by the three flashing
LEDs, and sent to the cen-
tral through the connection
terminal MASK.
This signal remains until it
is removed the cause that
generated it.
The enabling of Antimask
function will be active only
after the closing of the plas-
tic front and will bring the sensor in a condition to MaskAdjust. In
this condition, in which the LEDs will flash alternately for about 60
seconds, the sensor will calibrate its antimask levels.
Closed the Plastic Front is therefore necessary to remove your
hands from the sensor, and do not move and do not put anything
in its immediate vicinity.
At the end of MaskAdjust the sensor will be ready for operation.
You automatically have two levels of sensitivity of the AntiMask
selecting the operation OUTDOOR/INDOOR:
INDOOR : maximum of sensitivity
OUTDOOR: optimized sensitivity on atmospheric disturbances
EXCLUSION of MW’s ANTIMASK
-
DipSwitch N°4 in pos. ON
You may exclude the Antimask of Microwave in installations that
presenting solid bodies in motion in the immediate vicinity of the
sensor and which could cause Antimask alarms : Blinds of metal,
shutters of metal, etc.
INDOOR /OUTDOOR
-
Dip Switch n° 2 in pos OFF Outdoor / in pos
ON Indoor
You have the ability to select the most suitable algorithm, such as
sensitivity and speed, to the type of installation chosen in order
to reduce false alarms and to have always the highest detection
capability in the installation you have choose.
INDOOR has a capacity of detection and false alarm rejection
typical of indoor volumetric sensors.
In OUTDOOR, the detection capability has been optimized
considering the possible disturbances caused by atmospheric