PET IMMUNITY

If there is the possibility of transit of pets in the protected zone, 

use the Blinding’s lens provided by applying it* on the lens so as 

to leave uncovered only the two upper zones.
The result is it in the figure below. 

TIPS FOR INSTALLATION

In indoor installations, prefer placement of the sensor toward the 

inside of the room and away from operating machinery and heat 

sources. Avoid to direct it toward the windows exposed to the 

sunny. In outdoor installations, prevent that the sun’s rays, es-

pecially during the hottest hours of the day, come directly to the 

infrared sensing element.

Aplication of Blinding’s lens

Remove the lens blocker by unscrewing the screws A and B.

Remove the lens and apply the adhesive “Blinding’s lens” leaving

uncovered only the two highest zones.

Refit the lens and the lens blocker by doing the reverse procedure. 

SETTING

Through the positioning of the 5 Dip Switches is possible to adapt 

the sensor working to the your installing needs. 

* Note: Depending on your needs, you can make a different

partitioning of the areas of the infrared detection by cutting

appropriately the Blinding’s lens and leaving uncovered other

zones of the the lens

DIP SWITCH

1 GLOBAL MASK IR + MW

ON = ACTIVED

OFF = DEACTIVATED

2 OUTDOOR / INDOOR

ON = INDOOR

OFF = OUTDOOR

3 CROSSING / APPROACH

ON = APPROACH

OFF = CROSSING

4 MW ANTIMASK

DEACTIVATION

ON = DEACTIVED

OFF= ACTIVATED

5 LED OFF

ON = LED OFF

OFF = LED ON

GLOBAL ANTIMASK

 

- Total Antimask MW + IR

  DipSwitch N°1 in pos. ON 

and Plastic Front closed

Any element that can mask 

the MW or the lens of the 

IR generates an alarm dis-

played by the three flashing 

LEDs, and sent to the cen-

tral through the connection 

terminal MASK.

This signal remains until it 

is removed the cause that 

generated it.

The enabling of Antimask 

function will be active only 

after the closing of the plas-

tic front and will bring the sensor in a condition to MaskAdjust. In 

this condition, in which the LEDs will flash alternately for about 60 

seconds, the sensor will calibrate its antimask levels.

Closed the Plastic Front is therefore necessary to remove your 

hands from the sensor, and do not move and do not put anything 

in its immediate vicinity.

At the end of MaskAdjust the sensor will be ready for operation. 

You automatically have two levels of sensitivity of the AntiMask 

selecting the operation OUTDOOR/INDOOR:

  INDOOR : maximum of sensitivity

  OUTDOOR: optimized sensitivity on atmospheric disturbances

EXCLUSION of MW’s ANTIMASK

 - 

DipSwitch N°4 in pos. ON

You may exclude the Antimask of Microwave in installations that 

presenting solid bodies in motion in the immediate vicinity of the 

sensor and which could cause Antimask alarms : Blinds of metal, 

shutters of metal, etc.

INDOOR /OUTDOOR

 - 

Dip Switch n° 2 in pos OFF Outdoor / in pos 

ON Indoor

You have the ability to select the most suitable algorithm, such as 

sensitivity and speed, to the type of installation chosen in order 

to reduce false alarms and to have always the highest detection 

capability in the installation you have choose.

  INDOOR has a capacity of detection and false alarm rejection  

  typical of indoor volumetric sensors.

  In OUTDOOR, the detection capability has been optimized 

  considering the possible disturbances caused by atmospheric 

Содержание AF969F

Страница 1: ...5 Per installazione diretta a muro fissare il fondo con le apposite viti tramite le sedi A e B 6 Per installazione con staffa angolare fissare prima la staffa alla parete con le apposite viti e poi f...

Страница 2: ...lente eseguendo la procedura inversa Nota la portata del sensore stabilita dal trimmer in funzione della massa di un corpo umano Animali di grande taglia cavalli mucche od oggetti in movimento di gros...

Страница 3: ...ntifichi un sito esterno con bassa possibilit di interferenza o un sito interno con alta possibilit di falso allarme ATTRAVERSAMENTO AVVICINAMENTO Dip Switch n 3 in pos OFF Attraversamento in pos ON A...

Страница 4: ...al slot for a high immunity of the infrared section to all of the phenomena disorders that do not show up in its field of detection view Filter LED to enable the vision of the detection only close of...

Страница 5: ...ut normally 12V TAMP ALL MASK NC NC NC TIPS FOR INSTALLATION In indoor installations prefer placement of the sensor toward the inside of the room and away from operating machinery and heat sources Avo...

Страница 6: ...hat can mask the MW or the lens of the IR generates an alarm dis played by the three flashing LEDs and sent to the cen tral through the connection terminal MASK This signal remains until it is removed...

Страница 7: ...e This is because the infrared detection is affected by ambient temperature from clothing of the intruder the presence absence of wind etc The trimmer thus automatically adjusts the detection capabili...

Страница 8: ...ercial en vigueur Les produits AVE sont des produits d installation Ils doivent tre install s par des personnes qualifi es conform ment aux normes en vigueur et aux usages en respectant les instructio...

Отзывы: