at a distance by an intruder, but allowing the verification of
operation only in the immediate vicinity of the sensor by the
user;
- hide aesthetically the closing screw of the detector
Closing screw
Card screw
Plastic
Bottom
Filter Led
Infrared
Optics
Circuit
Board
Rubber
Intermediate Plastic
Bottom
Location D
Location C
Centering
Guidance
Arrows
HUB CP
HUB P
Angle Bracket’s
Screw
Location B
Location A
Angle Bracket’s
Screw
Screws
for wall
mounting
Cable
entry
Plastic
Bottom
Angle
Bracket
TERMINAL
–
INHIBIT: input signal to detect if the
system is armed or not armed.
Power supply input (12V dc)
Normally closed tamper contact
Normally closed alarm output
Closed contact antimask
output, normally.
12V
TAMP
ALL
MASK
+ –
NC
NC
NC
TIPS FOR INSTALLATION
In indoor installations, prefer placement of the sensor toward the
inside of the room and away from operating machinery and heat
sources. Avoid to direct it toward the windows exposed to the
sunny. In outdoor installations, prevent that the sun’s rays, es-
pecially during the hottest hours of the day, come directly to the
infrared sensing element.
For protection of walls, avoid that a sensitive area of infrared is in
contact with the wall, in order to don’t cancel the benefit of the
dual-element infrared sensor.
Overcome this by mounting the sensor detached from the wall
(see table),
or orienting the sensor of a few degrees (<10 °) using the optional
accessory Swivel Bracket Hub P + HUB-CP.
To prefer installations where there is a wall / floor to delimit the
field of detection of the sensor. Do not point the sensor in a vac-
uum space.