S y m p t o m , P o s s i b l e C a u s e a n d R e m e d y
23
F a u l t D i a g n o s i s
S Y M P T O M
P O S S I B L E C A U S E
R E M E D Y
PA G E R E F
Pneumatic motor
Air leak from motor
Check for worn seals. Replace.
-
runs slowly
Low air pressure
Increase
-
Air way blockage
Clear restriction in air supply
-
Worn drive screw
Replace
-
Rotor blades jamming
Lubricate tool through air inlet
-
Rotor blades worn
Replace rotor blades
-
Insert does not
Stroke incorrectly set
Adjust
-
deform properly
Air pressure outside the tolerance
Adjust
-
Low oil level
Prime tool
-
Insert out of grip
Check grip range of insert
-
Drive screw turns
Worn or damaged drive shaft
Replace
-
independent of
Worn or damaged drive screw
Replace
-
motor
Adaptor nut loose
Tighten
-
Insert will not
Incorrect insert thread size
Change to correct insert
-
place onto
Incorrect drive screw fitted
Change to correct drive screw
-
drive screw
Worn or damaged drive screw
Replace
-
Nose equipment incorrectly assembled
Disconnect air supply, re-fit nose equipment
carefully
-
Tool is jammed on
Excessive stroke
DO NOT DEPRESS TRIGGER. Depress
placed insert
Defective insert
emergency spin-off button. Tool should spin
Worn or defective drive screw
off. Reset stroke. If not, disconnect air to tool.
Insert a 4 mm pin through nose casing slots
into Spindle 43. Turn until drive screw leaves
insert. Use new insert AND drive screw.
-
Drive screw breaks
Stroke of tool excessive
Reset stroke
-
Side load on drive screw
Hold tool square to application when placing
-
Insert -
Tool does not spin
Screw adaptor nut loose
Tighten
-
on
No air supply
Connect
-
Item numbers in bold refer to the Base Tool General Assembly drawing and Parts List pages 16-17.
Other symptoms or failures should be reported to your local Avdel authorised distributor or repair centre.