Replacing an S8100 Media Server’s hard drive
Upgrade steps
18
Upgrade Job Aids for S8100
November 2003
35
BS
– Shutdown every application.
Execute
shutdown all
.
36
BS
– After the shutdown finishes, restart every
application.
Execute
start
all
.
37
BS
– Monitor the startup’s progress.
Execute statapp.
38
Verify that call processing comes into service.
39
Verify that voice messaging comes into service.
40
BS
– Telnet into the LAC window from the
bash.
Execute
telnet 127.1 and logon using lucent3.
41
LAC
– Open a SAT window.
Type
multivantage
to open a SAT window. (The
terminal type is W2KTT.)
42
SAT
– Verify that there is no translation
corruption.
If there are corrupted translations, a message will appear
when the SAT window opens.
43
SAT
– Verify that no major or minor alarms are
present.
Run
display alarms
.
44
SAT
– Verify outgoing alarm reports link to
INADS.
Run
test inads-link
.
45
SAT
– Verify no-license/emergency numbers.
Type
change system-parameters features
.
See ‘‘Administer No-License/Emergency Numbers’’ in
Installation and Upgrades for the Avaya S8100 Media
Server with the Avaya G600 and the Avaya CMC1 Media
Gateways, 555-233-146.
46
SAT
– Save translations.
Run
save trans
.
47
SAT
– Logoff SAT and exit LAC.
a
Type
logoff
and respond with
y
to close the SAT
session.
b
Type
bash
to go to the bash shell.
48
BS
– Verify Intuity alarms.
Type
logsend -tTST
.
49
BS
– Verify GAM alarms.
Type
wrntevent GAM 0 9991
.
Note: This causes a Major GAM alarm. After the system
has called out, enter
cleargamalarm all
at the
BASH
prompt
to retire the alarm. This alarm also generates a
Maestro case that the INADS group will need to close.
50
BS
– Close the bash windows.
a
Type
exit
to close the bash window.
b
Type
exit
to close the LAC window.
Step
Details