BS; Reviewed:
SPOC 2/14/2005
Solution & Interoperability Test Lab Application Notes
©2005 Avaya Inc. All Rights Reserved.
15 of 22
RAD-IP-Mux.doc
•
Set the field
Is one endpoint remoted via DS1 Converter Complex?
to
yes.
This enables
the configuration of ‘fiber connectivity’ over the T1s using the DS1 Converter board and
pops up the related fields on the form.
•
For Endpoint 1 (main PN),
o
Set the board location for the switch node interface (sni) by setting
Board Location
field. For example, the location of the sni board is
1E20.
o
Set the DS1 Converter board location by setting
DS1CONV Board Location
field.
For example, the location of the DS1 Converter is
1E21.
•
For Endpoint 2 (remote PN),
o
Set the board location for the expansion interface (ei) by setting
Board Location
field. For example, the location of the EI board is
11A01.
o
Set the DS1 Converter board location by setting
DS1CONV Board Location
field.
For example, the location of the DS1 Converter is
11A02.
•
Set
Converter
to
Yes ,
the
Type field
to
Avaya,
and the
Type of Transceivers
to
A
The following SAT screen displays Page 1 of the fiber-link configuration:
display fiber-link 11 Page 1 of 2
FIBER LINK ADMINISTRATION
Fiber Link #: 11
Is one endpoint remoted via DS1 Converter Complex?
yes
ENDPOINT-1 ENDPOINT-2
(A-PNC) (A-PNC)
Board Location:
01E20
Board Location:
11A01
Board Type: sni Board Type:
ei
DS1CONV Board Location:
01E21
DS1CONV Board Location:
11A02
DS1CONV Board Type: TN1654 DS1CONV Board Type:
TN1654
Fiber Translation: Converter?
yes
Type of Transceivers:
A
Converter Type:
Avaya
On the second page of the
add fiber-link x
form, configure the T1 parameters for each T1 facility,
as follows:
•
Set
Facility Installed
to
Yes
for each T1 facility that is connected via T1 cable to RAD
IPmux-14 device. In this example, all the T1s (A, B, C and D) are installed and connected.
•
Set the
Bit Rate
field to
1.544
. This sets all the ports on DS1 Converter board to T1.
•
Set the
Line Coding
to
b8zs
for all the facilities.