Chapter 4
CLI – Architecture, Access & Conventions
28
P333R User’s Guide
Establishing a Serial Connection
Perform the following steps to connect a terminal (physical or emulation) to the
P330 Master Switch Console port for configuration of Stack or Router parameters:
1
Use the serial cable supplied to attach the RJ-45 console connector to the
Console port of the P330 Master Switch. Connect the DB-9 connector to the
serial (COM) port on your PC/terminal.
2
Ensure that the serial port settings on the terminal are 9600 baud, 8 bits, 1 stop
bit and no parity.
3
When you see the “Welcome to P330” menu and are prompted for a Login
Name, enter the default login. The default login is
root
.
4
When you are promoted for a password, enter the user level password
root
.
5
Now you can establish a connection to the Router or the Master switch
(indicated when the SYS front panel LED is ON) using the Session commands
(see P330 Sessions for details) and begin the configuration of Module, Stack or
Router parameters.
Establishing a Telnet Connection
Perform the following steps to establish a Telnet connection to the P332G-ML for
configuration of Stack or Router parameters. You can Telnet either the Stack Master
IP address or directly to one of the Router IP address:
1
Connect your station to the network.
2
Verify that you can communicate with the P332G-ML using Ping to the IP of the
P332G-ML. If there is no response using Ping, check the IP address and default
gateway of both the P332G-ML and the station (see Assigning P330’s IP Stack
Address page 39 and Assigning P332G-ML Initial Parameters for Router Mode
on Page 40).
Note:
The P332G-ML default IP address is 149.49.35.
214
and the default subnet
mask is 255.255.255.0.
3
From the Microsoft Windows
®
taskbar of your PC click
Start
and then
Run
(or
from the DOS prompt of your PC), then start the Telnet session by typing:
telnet
<P330_IP_address>
For example:
telnet 149.49.35.214
4
If the IP Address in Telnet command is the IP address of the stack, then
connection is established with the Switch CLI entity of the Master module.
If you want to connect to the Router CLI entity, use the session command.
If the IP address in the Telnet command is of the router, connection is
established to the Router CLI entity in the router module.
Содержание P333R
Страница 1: ...Avaya User s Guide AVAYA P333R STACKABLE 3RD LAYER SWITCH SOFTWARE VERSION 3 11 July 2002 ...
Страница 2: ......
Страница 16: ...Table of Contents xiv Avaya P333R User s Guide ...
Страница 18: ...List of Figures xvi Avaya P333R User s Guide ...
Страница 20: ...List of Tables xviii Avaya P333R User s Guide ...
Страница 54: ...Chapter 4 CLI Architecture Access Conventions 34 P333R User s Guide ...
Страница 246: ...Chapter 7 Cajun Campus CLI Layer 3 226 Avaya P333R User s Guide ...
Страница 249: ...Appendix A Embedded Web Manager Avaya P333R User s Guide 229 The welcome page is displayed Figure A 1 The Welcome Page ...
Страница 266: ...Appendix B Specifications 246 Avaya P333R User s Guide ...