background image

AVAYA Merlin Legend

 

 

 

 

The above information is provided by AVAYA Inc. as a guideline.  See disclaimer on page 1 

6. 

DTMF On Time (ms)

 = 80 

7. 

Search Entire String for Reason Code

 = Leave blank 

8. 

Location of Inband reason code

 = 1 

9. 

Log Inband Packets

 = Leave blank 

10. 

Fixed Length Packets

 = Leave blank 

11. 

Filler Character

 = <None> 

12. 

Delimiter Character

 = # 

13. 

Right Alignment of Digits in a Field

 = Leave blank 

14. 

Request String Supported

 = Leave blank

 

ƒ

 Access 

the 

Protocol Settin

gs button within the same tab 

1. 

Call Packet Type

 = Direct Call 

2. 

Codes for Call Type:

 

Code 1

 = 00 

3. 

Field Type Settings:

 

- Called 

Id

 = Leave blank 

- Calling 

Id

 = 2 (Under the Sequence Number column) 

Trunk Id

 = Leave blank

 

4. Next 

select 

Call Packet Type 

= Divert: 

5. 

Codes for Call Type:

 

Code 1

 = 02 (Internal call routing for All Call) 

Code 2

 = 03 (External call routing for All Call) 

6. 

Field Type Settings

Called Id

 = 3  (Within the Sequence Number column) 

Calling Id

 = 2  (Within the Sequence Number column) 

Trunk Id

 = Leave blank 

7. 

Select 

OK

 to save changes

 

ƒ

 Within 

the 

Inband

 tab, access the 

MWI Settings 

button 

1. 

Port Group Name

 = Select the port group to be used for MWI 

2. 

Max. MWI Sessions

 = Enter the maximum number of MWI sessions 

allowed at one time.  The Default value is 1 

3. 

Indicator On/Off signals must use same port

 = Click to turn on 

4. 

Indicator On

:      

Prefix

 = #53     

Suffix

 = Leave blank 

5. 

Indicator Off

:      

Prefix

 = #*55  

Suffix

 = Leave blank 

6. Select 

OK

 to save changes 

 

Note:

  The numeric values of #53 and #*53 for MWI on/off shown above are 

examples. Confirm what the MWI Feature Access Codes for these 
specific settings are on your PBX. The settings in the PBX for MWI 
on/off must match those for MWI on/off in the MM. 

 

After making these changes, return to “Configuring the voicemail system” within 
the Message Application Server Installation Guide.  Ensure you are prompted to 
restart the Message Application Server services to apply these changes. 

Содержание Magix

Страница 1: ... PBX and the Avaya Message Application Server transmits both call information and voice communications 2 0 AVAYA MESSAGE APPLICATION SERVER REQUIREMENTS Dialogic D 41JCT LS or D 120JCT LS cards 4 and 12 port cards MAS requirements Supported Releases 1 1 2 0 3 x 4 0 5 x 3 0 PBX HARDWARE REQUIREMENTS Station appearances one per MAS port PBX hardware requirements Analog Interface Card 012 or 016 card...

Страница 2: ... RJ11 four wire telephone cord one per MAS port NOTE The customer must provide the necessary hardware 3 1 PBX SOFTWARE REQUIREMENTS PBX software requirements Minimum Software R2V1 Hybrid PBX configuration see section 8 2 4 0 SUPPORTED INTEGRATION FEATURES Supported integration features 9 Items are supported System Forward to Personal Greeting All Calls 9 Ring no answer 9 Busy 9 Busy No Answer Stat...

Страница 3: ... the screens seen while programming are identical For details refer to the Avaya Merlin Legend Communications System Programming Manual Once you are logged into the Legend system the System Programming menu will appear as follows System Programming Make a selection System Extensions SysRenumber Options Operator Tables LinesTrunks AuxEquip Exit NightSrvce System Programming Menu The Legend system m...

Страница 4: ...parameter should be disabled From the VMS AA screen select TT Duration This parameter should be set to 75 milliseconds If it is not erase the current setting using the Drop key and enter 75 Press enter to save your entry From the VMS AA screen select TT Interval This parameter should be set to 50 milliseconds If it is not erase the current setting using the Drop key and enter 50 Press enter to sav...

Страница 5: ... added to the calling group When all MAS ports have been added verify your entries by using the Inspect key on the console If you are using a PC to program the Legend press PgDn and then the F5 key This will list all members of the calling group Press exit to return to the Group Calling menu Assign the Group Type for the MAS calling group This parameter tells the Legend to send mailbox ID informat...

Страница 6: ... Group Coverage Delay Interval Erase the current entry using the Drop key Now specify the number of desired rings from 1 to 9 Press enter To return to the System Programming menu press exit To assign the call coverage to the MAS subscribers perform the following programming From the System Programming menu select Extensions Use the More key to reach the second page of the menu At this screen choos...

Страница 7: ...System then select Back Restore 6 0 CONFIGURING THE MESSAGE APPLICATION SERVER Configuring the MAS platform for proper PBX integration requires configuring several containers accessed within the Voice Mail System Configuration application and a certified MM engineer Configuring the MAS Access the Voice Mail System Configuration application from the MAS program group Expand all fields so all applic...

Страница 8: ...ring Leave Blank 3 Hangup String Timeout ms 0 4 Minimum Duration For Drop in Loop Current ms 300 5 Maximum Silence before Hanging Up ms 6000 6 Select OK to save changes Select Voice Server and access Telephony Interface Dialogic Analog 1 Select the Analog tab 2 Playback Volume 2 3 Number of Ports Enter the number of ports in your system Note The MAS service must be restarted to allow port enabling...

Страница 9: ...pe Settings Called Id 3 Within the Sequence Number column Calling Id 2 Within the Sequence Number column Trunk Id Leave blank 7 Select OK to save changes Within the Inband tab access the MWI Settings button 1 Port Group Name Select the port group to be used for MWI 2 Max MWI Sessions Enter the maximum number of MWI sessions allowed at one time The Default value is 1 3 Indicator On Off signals must...

Страница 10: ...n is not currently supported for Legend systems configured as key systems 8 3 With release 1 software stations on the Legend cannot all calls forward to the pilot number of a calling group hunt group The do not disturb feature on the Merlin Legend is suggested as an alternative This feature when activated at a station will suppress the ringing of incoming external calls External calls will then fo...

Страница 11: ... RTO findings Version F 04 11 06 Updated to meet release MM 3 0 Version G 06 01 07 Updated Inband Tab MWI Settings at end of Section 6 0 Made note red Version H 05 05 08 Updated to support MM 4 0 Version I 05 16 08 Updated diagram page 1 Version J 2 02 09 Updated to support MM 5 0 Version K 07 09 Updated to support MM 5 1 2009 AVAYA Inc All rights reserved All trademarks identified by the SM and T...

Отзывы: