11. Attach the negative voltage lead to the negative terminal on the power supply to
insert a lock washer between the crimp lug and each hex nut.
12. Use a 7/16 inch hex wrench to tighten the hex nut on each terminal.
13. Attach the earth ground cable to the system or rack ground for your DC input power
source.
14. Use a Phillips screwdriver to replace the plastic safety cover on the power supply.
15. Firmly slide the power supply all the way into the bay. See
retaining screws on the DC power supply
on page 35.
16. Tighten the retaining screws to firmly seat the power supply.
17. Attach the positive and negative terminal leads to the DC input power source
according to the proper safety and technical specifications for your 48 V power
distribution system.
DC power supply installation
32 Installation — DC Power Supply
May 2011
Содержание Ethernet Routing Switch 8300 Series
Страница 1: ...Installation DC Power Supply Avaya Ethernet Routing Switch 8300 4 2 NN46200 310 02 03 May 2011...
Страница 16: ...Regulatory Information and Safety Precautions 16 Installation DC Power Supply May 2011...
Страница 36: ...DC power supply installation 36 Installation DC Power Supply May 2011...
Страница 48: ...Technical specifications 48 Installation DC Power Supply May 2011...
Страница 50: ......