Under JDM, the rear ports are be grayed out and not selectable in the switch view if the ports are
in stacking mode.
Figure 3: ERS 2500 JDM display
Power over Ethernet (POE) limitations
The status for the PoE port can appear incorrectly as InvalidPD rather than detecting. This
occurs if the PD detect type on an ERS 2500-PWR is set to 802.3af and legacy while a PoE
port on the switch is connected to a non-PoE device.
Be aware that this is a hardware limitation that is caused by the capacitive detection method
used in the legacy mode (versus resistive/current based detection used in 802.3af compliant
mode). Some devices are always errantly detected because they match the capacitive
signature, dependent on the environment, cabling, etc.
Power over Ethernet (POE) limitations
Troubleshooting
November 2010 7