Page 24 - Installation
Page 24
DECT - Installation Manual
Altering DAB (IWU) Card Settings
38HBKD0001SAH – Issue 14 (27th October 2003)
Altering DAB (IWU) Card Settings
The
CCFP Setup
page of CCFP Administration allows the individual
configuration of IWU cards in the system plus some system wide (Global)
values. Alter the settings to match those required by the PABX analogue
connections.
Global CCFP Setup
–
Exchange Code:
This digit is prefixed to dialing from the DECT handsets (the default is
0). When used in conjunction with an INDeX switch,
leave this field
blank
as all call routing is done by ARS on the INDeX switch.
–
Ringing Mode:
Select
Exchange
ringing unless this causes problems.
–
Date & Time:
Shown as day, month, hours and minutes in 24-hour format. The
system does not use a year setting.
–
Recall Mode:
By default all DAB cards including DAB-ER use Loop Break. Ensure
that DAB-ER cards are reset to Earth Pulse after installation unless
required otherwise.
Individual IWU Card Setup:
To return a DAB (IWU) card to default state use the
Options
|
Preferences
|
Advanced Options
menu to select and then default the
card. Most of these settings should only be altered to match the analogue
lines to which the DAB (IWU) is attached. The only settings which may
require adjustment is the Suppression box.
–
Suppression:
The DAB Boards supports various levels of noise suppression for
different environments. If a value is selected which is not supported by
the particular PCS Level of the DAB Board, a message to that effect is
displayed.
–
Save IWU Data/Cancel Edits:
Changes to individual DAB Boards are saved to the DCU when
Save
IWU Data
is clicked. The original settings, when the DCU was last
accessed, are restored for the individual DAB Board when
Cancel
Edits
is clicked.