BCM450 Hardware & Installation
78
NN40011-001 Issue 1.2 BCM450 Rls 6.0
8. Carefully lift the battery out of its socket. Do not use any type of tool to
remove the battery.
9. Carefully align the new battery with the top of the battery socket.
10. The positive side of the battery must face upwards.
11. Gently push down until the battery snaps into the socket.
12. Reinstall the base function tray.
13. Restore the BCM system to operation.
Resetting the BCM450 using the Reset Button
The BCM450 can be reset by pushing the reset button situated at the front of
the BCM450. The length of time that the button is pressed determines the
type of reset that is performed.
If the reset button is pressed for less then 5 seconds, the BCM will
begin the reboot process which will complete in less then 30 seconds.
If the BCM450 Reset Button is held for 5 seconds, the BCM450 will
immediately reboot.
Data loss may occur
.
Note
: The immediate reboot option should only be utilized when the BCM450
is not responding to normal reboot operations or is entirely non-responsive.
If the BCM450 system has been shut down from the CLI, the Reset
Button must be held for 5 seconds to initiate the reboot process.
Upon restart caused by a press of the Reset Button, the BCM450 will
wait up to 10 seconds for a user to login to the BCM Maintenance CLI.
If no user logs in to the Maintenance CLI within this 10 second period,
the BCM will boot the
BCM‘s operating system.