Table 2: Available system power for Ethernet Routing Switch 8306 and 8310 chassis
Power
Supply
Power
supply
rating
Number
of power
supplies
Redundancy
Module
PoE
Fans
Tot
al
8301AC
100-120VA
C
1
No
600 W
450 W 90 W
114
0 W
2
Yes 1+1
600 W
450 W 90 W
114
0 W
1140 W
3
Yes 2+1
1290 W
900 W 90 W
228
0 W
200-240VA
C
1
No
780 W
900 W 90 W
177
0 W
2
Yes 1+1
780 W
900 W 90 W
177
0 W
1770 W
3
Yes 2+1
1650 W
1800
W
90 W
354
0 W
8302AC
100-120VA
C
1
No
535 W
225 W 90 W
850
W
2
Yes 1+1
535 W
225 W 90 W
850
W
850 W
3
Yes 2+1
1160 W
450 W 90W
170
0 W
200-240VA
C
1
No
860 W
450 W 90 W
140
0 W
2
Yes 1+1
860 W
450 W 90 W
140
0 W
1400 W
3
Yes 2+1
1810 W
900 W 90 W
280
0 W
If you install a redundant power supply, power available for PoE is always determined on a N
+1 redundancy. If you have one or two power supplies in the chassis, you allocate PoE power
equivalent to one power supply. If you have three power supplies in the chassis, you allocate
PoE power equivalent to two power supplies.
The following table lists the input power specifications for each of the modules.
Table 3: Ethernet Routing Switch 8300 modules power specification
Module Power
Module
Input Power
Heat Dissipation
Output PoE
8394SF/CPU
120 W
341 Btu/hr
0 W
Determining the number of AC power supplies
Planning and Engineering — Power Considerations
May 2011 25
Содержание 8308XL
Страница 18: ...New in this release 18 Planning and Engineering Power Considerations May 2011 ...
Страница 20: ...Introduction 20 Planning and Engineering Power Considerations May 2011 ...
Страница 32: ...Power considerations 32 Planning and Engineering Power Considerations May 2011 ...
Страница 36: ...Power cord specifications 36 Planning and Engineering Power Considerations May 2011 ...
Страница 42: ...Translation of safety messages 42 Planning and Engineering Power Considerations May 2011 ...
Страница 44: ......